Vibronic level switch Liquiphant FTL50/H, FTL51/C/H FTL51H

Brand: Endress+Hauser

Vibronic level switch Liquiphant FTL50/H, FTL51/C/H FTL51H

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Process pressure / max. overpressure limit:
Vacuum...64 bar
(Vacuum...928 psi)
Min. density of medium:
0.5g/cm³
(0.4g/cm³ optional)
Process temperature:
-50 °C...+150 °C
(-58 °F...+302 °F)

Field of application

The FTL51H Liquiphant is a vibronic level switch designed specifically for the food and life sciences industry. This device, equipped with an extension tube, is ideal for overfill prevention or pump dry-run protection. It is also suitable for use in hazardous areas, ensuring safety and efficiency in demanding environments.

Specifications

Product Family

  • Liquiphant

Density

Characteristic / Application

  • Liquiphant M Density
  • with Density Computer FML621
  • Temperature and pressure measurement
  • Modular & completely welded housing concept
  • Focus Food & Pharma
  • Surface up to 0.3 µ
  • Variable sensor length up to 3 m (6 m option)

Supply / Communication

  • Transmitter power supply (MUS)

Ambient temperature

  • -50...70°C
  • -50...60°C for hazardous applications

Process temperature

  • 0...80°C (validity of accuracy data)
  • -50...0°C / 80...150°C (with reduced technical data)

Process pressure

  • 0...25 bar
  • >25...64 bar (with reduced technical data)

Wetted parts

  • 316L

Hygienic

  • 3A
  • EHEDG

Sensor length

  • 115...3000 mm
  • >3000...6000 mm (Option)

Output

  • Pulse

Certificates / Approvals

  • ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Specialities

  • Commissioning with ReadWin2000

Components

  • Density Computer FML621

Other approvals and certificates

  • SIL2/ SIL3

Point Level / Liquids

Characteristic / Application

  • Premium device for point level detection
  • in hygienic/aseptic applications.
  • Focus Food & Beverage and Life Sciences.
  • Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
  • Modular & completely welded housing concept,
  • Wide range of certificates.

Specialities

  • Plug and play functionalities,
  • Surface finish: mechanical or electro-polished,
  • Density/Concentration measurement,
  • SIL 2/3 according to IEC 61508

Supply / Communication

  • PROFIBUS PA,
  • 19 ..253V AC,
  • 10...55V DC-PNP,
  • 19...253V AC or 19...55V DC with relay DPDT,
  • 8/16mA,
  • NAMUR,
  • PFM

Ambient temperature

  • -50 °C...+70 °C
  • (-58 °F...+158 °F)

Process temperature

  • -50 °C...+150 °C
  • (-58 °F...+302 °F)

Process pressure / max. overpressure limit

  • Vacuum...64 bar
  • (Vacuum...928 psi)

Min. density of medium

  • 0.5g/cm³
  • (0.4g/cm³ optional)

Main wetted parts

  • 316L

Process connection

  • Threads (for weld-in adapter):
  • G3/4A, G1A,
  • Flange:
  • DN25...DN100,
  • ASME 1"...4",
  • JIS 25A...100A

Process connection hygienic

  • Tri-Clamp,
  • DIN 11851, DIN11864-1
  • Ingold,
  • Flush mount,
  • DRD,
  • SMS1145,
  • Varivent (Varinline)

Sensor length

  • Short tube (Liquiphant II)
  • 148mm…3000mm (6,00…118")

Communication

  • PROFIBUS PA

Certificates / Approvals

  • ATEX, IEC Ex, FM, CSA C/US, TIIS,
  • INMETRO Ex, NEPSI Ex

Safety approvals

  • Overfill protection WHG,
  • SIL 2/ SIL 3

Design approvals

  • Inspection certificate 3.1, EN10204,
  • CoC ASME BPE,
  • Conformity to cGMP,
  • EU Food Contact Material (EC) 1935/2004,
  • US Food Contact Material FDA CFR 21,
  • CN Food Contact Material GB 4806,
  • Declaration of Conformity ASME B31.3,
  • AD2000,
  • CRN approval

Hygienic approvals

  • 3-A,
  • EHEDG,
  • CoC-ASME BPE

Marine approval

  • GL/ ABS/ DNV

Options

  • Customized settings (Density)

Components

  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR

Successor

  • FTL63
show more