Design
- Per EN 837-3 and HVac regulations
Accuracy
- ± 3.0 % of Full Span
- ± 5.0 % of Full Span, Ranges ≤ 0.5 inH₂O (125 Pa)
Ranges
- 0 / 0.2 inH₂O (50 Pa) up to 0 / 50 inH₂O (12,500 Pa)
Pressure Units
- inH₂O (Standard)
- Other available units: kPa, Pa, mmH₂O, cmH₂O, mmHg
Compound Ranges
- Starting from -0.1 / +0.1 inH₂O (-25/+25 Pa) (Other Pressure units and dual scales are available)
Pressure Limitation
- Steady: Full Scale Value
- Fluctuating: Full Scale Value
Maximum Working Pressure (Static Pressure)
Temperature Limits
- Ambient: -22° F to 176° F (-30° C to +80° C)
- Media: 3° F to 122° F (-16° C to +50° C)
Temperature Error
- Additional error when temperature changes from reference temperature of 68° F (20° C) ± 0.5 % of Span for every 18° F (10° K) rising or falling
Ingress Protection
- NEMA 3 (IP54 per EN 60529 / IEC 529)