Temperature Range
- Class A: without Neck Tube -30° to +150° C (-22° to +302° F), with Neck Tube -30° to +250° C (-22° to +482° F)
- Class B: without Neck Tube -50° to +150° C (-58° to +302° F), with Neck Tube -50° to +250° C (-58° to +482° F)
Temperature at the Connector
Measuring Element
- Pt100 (Measuring Current: 0.1 ... 1.0 mA)
- Pt1000 (Measuring Current: 0.1 ... 0.3 mA)
Connection Method
- 2-Wire The lead resistance is recorded as an error in the measurement
- 3-Wire with a cable length of 30 m or longer, measuring deviations can occur
Tolerance Value of the Measuring Element Per IEC 60751
Electrical Connection
- M12 x 1 Circular Connector (4-Pin)
Explosion Protection
- Intrinsically safe to Ex i (ATEX) gas/dust (For further information see “Further Specifications for explosion-protected version”)