Temperature Engineered Solution TMS12

Brand: Endress+Hauser

Temperature Engineered Solution TMS12

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Xpert Xpert

Specs at a Glance

Operating temperature range:
Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200...600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °F
(-58…752 °F)
Max. immersion length on request:
up to 15.000,00 mm (590'')
Response time:
depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
Accuracy:
class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
Max. process pressure (static):
at 20 °C: 240 bar (3481 psi)

Field of application

The iTHERM TMS12 MultiSens Linear multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by creating detailed linear temperature profiles and features a diagnostic chamber to contain and monitor leakages through the primary seals. Easy process integration reduces installation time and thus maximizes plant availability.

Oil & Gas industry

Heavy chemical processes

Petrochemical industry

Features

  • Primary thermowell for superior mechanical strength and an easy replacement of individual inserts, which are available either with TC or RTD technology
  • Increased safety thanks to a diagnostic chamber able to contain the process in the event of leakages through the primary seals
  • Compliance to various safety standards (such as but not limited to ATEX, PED), electrical and Pressure Directive for easy process integration
  • High degree of customization thanks to a modular product design for maximum flexibility, easy installation and maintenance
  • On board electronic heat protection for long product lifetime
  • Superior mechanical strength and sensors replaceability thanks to a primary thermowell

Specifications

Industry

  • Power & Energy
  • Oil & Gas
  • Other industries

Product Family

  • iTHERM MultiSens

Thermometer

Characteristic / Application

  • metric style
  • imperial style
  • easy-to-use
  • suitable for hazardous areas
  • process connection: flanged
  • light chemical processes
  • linear sensor distribution
  • modular design
  • replaceable sensors during operation
  • diagnostic chamber

Thermowell / protection tube

  • with one primary thermowell (for replaceable sensors and increased mechanical protection)

Insert / probe

  • mineral insulated (MI) sensors in a primary thermowell

Outer diameter protection tube / Insert

  • 48,3mm (1 1/2")
  • 60,3mm (2")
  • 76,1mm (2 1/2")
  • 88,9mm (3")

Max. immersion length on request

  • up to 15.000,00 mm (590'')

Material protection tube/ thermowell

  • 1.4401 (316)
  • 1.4435 (316L)
  • 1.4541 (321)
  • 1.4845 (310L)
  • 1.4301 (304)
  • 1.4307 (304L)

Process connection

  • flange:
  • 1 1/2" ASME/ANSI B16.5 150
  • ...900
  • 2" ASME/ANSI B16.5 150
  • 3" ASME/ANSI B16.5 150
  • ..900
  • DN40 EN/DIN 1092.1 PN10
  • ...PN150
  • DN50 EN/DIN 1092.1 PN10
  • DN80 EN/DIN 1092.1 PN10

Tip shape

  • straight

Operating temperature range

  • Type K:
  • max. 1.070 °C
  • (max. 1.958 °F)
  • Type J:
  • max. 520 °C
  • (max. 968 °F)
  • Type N:
  • max. 1.100 °C
  • (max. 2.012 °F)
  • Pt100 WW:
  • -200...600 °C
  • (-328…1.112 °F)
  • Pt100 TF:
  • -50…400 °F
  • (-58…752 °F)

Max. process pressure (static)

  • at 20 °C: 240 bar (3481 psi)

Accuracy

  • class 1 acc. to IEC 60584
  • class Special ASTM E230 and ANSI MC 96.1
  • IEC60751 Class A
  • IEC60751 Class AA

Response time

  • depending on configuration:
  • TC:
  • t50 = 21 s
  • t90 = 52 s
  • RTD:
  • t50 = 42 s
  • t90 = 108 s

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

  • ATEX Ex db, Ex ia, Ex tb, Ex ia/db, Ex ia/tb
  • IECEx Ex db, Ex ia, Ex tb, Ex ia/db, Ex ia/tb
  • UL
  • FM
  • CSA
  • NEPSI

Certification

  • SIL (transmitter only)
show more