KS Sanitary Transducer
Brand: Ashcroft Inc
Does not ship to OH, United States
The Ashcroft® KS sanitary pressure transducer/transmitter combines proven thin film technology with diaphragm seal expertise.
Satisfying stringent requirements for cleanliness, this model is an ideal choice for any sanitary application.
Features- Pressure ranges from 30 to 1,000 psi
- ±1.00% of span accuracy
- All 316 stainless steel welded design
- Electropolished 316 SS diaphragm
- 1.5″ and 2.0″ Tri-Clamp™ process connection
- Voltage and 4-20mA output options
- Broad selection of pressure connections and electrical terminations
- 3A sanitary approved
Specifications
Brand
Reference Temperature
- 68° F (20° C)
Accuracy
- ± 1 % of Span
Stability
- ± 0.5 % Span/Year at Reference Conditions
Best Fit Straight Line (BFSL)
- ±0.75% of Span
Pressure Range
- Vacuum to 1,000 psi
- 30 to 1,000 psig, Compound to 100 psig
Durability
- >10 million Cycles
Span & Zero Effect
- ± 0.04 % of Span/°F
Position Effect
- < ±0.01 % of F.S.
Vibration Effect
- < ± 0.1 % of Full Scale Effect for 0 to 2000 Hz at 20g's in any axis
Shock Effect
- < ±0.05% F.S. Effect for 100g’s, 20 ms Shock in any axis
Output
- 1-5 Vdc, 3-Wire
- 1-6 Vdc, 3-Wire
- 4-20 mA, 2-Wire
- 1-11 Vdc
Approvals & Certifications
- 3-A Sanitary
Fill Material
- USP Grade 99.5 % Glycerin
Process Connection
- 1-1/2" Tri-Clamp
- 2" Tri-Clamp
Insulation Resistance
- 100 MΩ at 50 Vdc
Power Requirement
- 10-36 Vdc Unregulated
Supply Current
- < 3 mA for Voltage Output
Wetted Material
- Diaphragm & Process Connection: 316L Stainless Steel
Case Material
- 304 Stainless Steel
Environmental Protection
- NEMA 4X
Storage Temperature
- -54° to 121° C (-65° to 250° F)
Compensated Temperature
- -1° to 50° C (30° to 130° F)
Operating Temperature
- -28° to 82° C (-20° to 180° F)
Humidity
- 95 % RH, Non-Condensing
- Food & Daiy
- Pharmaceutical
- 3A Sanitary Applications