Specs at a Glance

Process temperature:
max. 400°C (752°F) (diptube)
Process pressure / max. overpressure limit:
Any (diptube)
Main wetted parts:
Non- contact

Field of application

The FQG63 source container is designed to hold the radioactive source during radiometric level, density and interface measurement. The radiation is damped in all directions as long as the source container is switched off. This guarantees highest safety for the personnel and a reliable measurement. If the source is switched on and lowered down into the process tank, it emits the radiation into all directions.

Designed to hold the radioactive source during density and interface measurement.

Off-position: Radioactive source located in the source container and screens off radiation

On-position: Radioactive source with the flexible extension located in the protection pipe inside the process vessel

Activity: 137Cs to 185.0GBq (5000mCi), 60Co to 3.7GBq (100mCi)

Temperature: -52 to +400°C (-62 to +752°F)

Pressure: No limitation (non-invasive, extraneous)

Features

  • Highest safety classification for the source supplied (DIN 25426/ISO 2919, typical classification C66646)
  • Reliable measurement due to lightweight container and almost spherical design which provides optimized screening
  • Flexible installation length up to 30m (98ft)
  • Manually operated and padlock, cylinder lock or locking bolt for fixing the switching position
  • Switch status easily identified
  • Compact device that is easy to mount; adapter and centering flange for existing vessel flanges

Specifications

Industry

  • Chemical
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)

Continuous / Liquids

Characteristic / Application

  • Source container with flexible extension element to position the source inside the process vessel (diptube)
  • Approximately 87kg
  • Adapter flange: 10kg

Specialities

  • With flexible extension element

Ambient temperature

  • -52 °C...+200 °C
  • (-61 °F...+392 °F)

Process temperature

  • max. 400°C (752°F)

Process pressure / max. overpressure limit

  • Any (diptube)

Main wetted parts

  • Non-contact

Process connection

  • Non-contact

Continuous / Solids

Characteristic / Application

  • Source container with flexible extension element to position the source inside the process vessel (diptube)
  • Approximately 87kg
  • Adapter flange: 10kg

Specialities

  • Control area calculation with Applicator

Ambient temperature

  • -52 °C...+200 °C
  • (-61 °F...+392 °F)

Process temperature

  • max. 400°C (752°F)

Process pressure / max. overpressure limit

  • Any (diptube)

Main wetted parts

  • Non-contact

Process connection

  • Non-contact

Density

Characteristic / Application

  • Source container with flexible extension element to position the source inside the process vessel (diptube)
  • Approximately 87 kg
  • Adapter flange: 10 kg

Ambient temperature

  • -52 °C...+200 °C
  • (-61 °F...+392 °F)

Process temperature

  • max. 400°C (752°F) (diptube)

Process pressure

  • Any

Wetted parts

  • Non-contact

Hygienic

  • Non-contact

Specialities

  • Control area calculation with Applicator

Point Level / Liquids

Characteristic / Application

  • Source container with flexible extension element to position the source inside the process vessel (diptube)
  • Approximately 87kg
  • Adapter flange: 10kg

Specialities

  • Control area calculation with Applicator

Ambient temperature

  • -52 °C...+200 °C
  • (-61 °F...+392 °F)

Process temperature

  • max. 400°C (752°F) (diptube)

Process pressure / max. overpressure limit

  • Any (diptube)

Main wetted parts

  • Non- contact

Process connection

  • Non- contact

Point Level / Solids

Characteristic / Application

  • Source container with flexible extension element to position the source inside the process vessel (diptube)
  • Approximately 87kg
  • Adapter flange: 10kg

Specialities

  • Control area calculation with Applicator

Ambient temperature

  • -52 °C...+200 °C
  • (-61 °F...+392 °F)

Process temperature

  • max. 400°C (752°F)
  • (diptube)

Process pressure / max. overpressure limit

  • Any (diptube)

Main wetted parts

  • Non- contact

Process connection

  • Non- contact

Process connection hygienic

  • Non- contact
show more