Coriolis flowmeter CNGmass D8CB

Brand: Endress+Hauser

Coriolis flowmeter CNGmass D8CB

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Specs at a Glance

Medium temperature range:
–50 to +125 °C (–58 to +257 °F)
Measuring range:
0 to 150 kg/min (0 to 330 lb/min)
Max. process pressure:
350 bar (5080 psi)
Max. measurement error:
Mass flow: ±0.5 % of batch
Wetted materials:
Mesuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)

Field of application

The CNGmass Coriolis flowmeter is specially designed for dispensers and measures mass flow of compressed natural gas with highest accuracy — independent of pressure and temperature.

Features

  • Iindependent of physical fluid properties such as viscosity or density
  • Excellent operational safety – reliable even under extreme process conditions
  • Fewer process measuring points – multivariable measurement of flow, density and temperature
  • Space-saving – installation without inlet/outlet runs, transmitter offers full functionality on the smallest footprint
  • Fast commissioning – pre-configured devices
  • Automatic recovery of data for servicing

Specifications

Industry

  • Oil & Gas

Product Family

  • CNGmass

Gas

Product headline

  • The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.

Sensor features

  • Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485.

Nominal diameter range

  • DN 8 to 25 (⅜ to 1")

Wetted materials

  • Measuring tube: 1.4435 (316L)
  • Connection: 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density

Max. measurement error

  • Mass flow: ±0.5 % of batch

Measuring range

  • 0 to 150 kg/min (0 to 330 lb/min)

Max. process pressure

  • 350 bar (5080 psi)

Medium temperature range

  • –50 to +125 °C (–58 to +257 °F)

Ambient temperature range

  • –40 to +60 °C (–40 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated

Degree of protection

  • IP66/67, type 4X enclosure

Display/Operation

  • No local operation
  • Configuration via operating tools possible

Outputs

  • None

Inputs

  • None

Digital communication

  • Modbus RS485

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO

Other approvals and certificates

  • 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • CRN

Liquids

Product headline

  • The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.

Sensor features

  • Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485.

Nominal diameter range

  • DN 8 to 25 (⅜ to 1")

Wetted materials

  • Mesuring tube: 1.4435 (316L)
  • Connection: 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density

Max. measurement error

  • Mass flow: ±0.5 % of batch

Measuring range

  • 0 to 150 kg/min (0 to 330 lb/min)

Max. process pressure

  • 350 bar (5080 psi)

Medium temperature range

  • –50 to +125 °C (–58 to +257 °F)

Ambient temperature range

  • –40 to +60 °C (–40 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated

Degree of protection

  • IP66/67, type 4X enclosure

Display/Operation

  • No local operation
  • Configuration via operating tools possible

Outputs

  • None

Inputs

  • None

Digital communication

  • Modbus RS485

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Pressure approvals and certificates

  • CRN

Material certificates

  • 3.1 material

No Videos