Accuracy
- BFSL: ± 0.5 % of Full Scale (The Effect of Linearity, Hysteresis & Repeatability Included)
Ambient Temperature Range
- -40° to 60° C (-40° to 140° F)
Approvals & Certifications
- CSA Approved Explosion-proof for Class I, Div. 1, Groups B, C, D, Class II, Groups E, F, G, Class III
Compensated Temperature
- -29° to 71° C (-20° to 160° F)
Consumption
- 3 mA for Voltage Output Models
- 4-20 mA for Current Output Model
Electrical Connectors
- 2 feet, 22 AWG Cable
- 3/4” NPT Female Conduit
Loop Resistance
- Current Outputs: 900 ohms, Max.
- Voltage Outputs: Min. 50 Kilohms
Media
- Compatible Gases
- Liquids & Gases
- Vapor
Output
- 1-5 Vdc
- 4-20 mA (Direct Current)
Power Requirement
- 12 to 30 Vdc (4-20 mA)
- 8 to 14 Vdc (1-5 Vdc)
Pressure Range
- bar: 0 to 34.4
- kPa: 0 to 3,447
- psid: 0 to 500
Process Temperature
- -40° to 100° C (-40° to 212° F)
Sensor Orientation
- ± 0.05 psi / 90° Rotation from Horizontal
Stability
- ± 1 % of Full Scale Per Year
Storage Temperature
- -40° to 100° C (-40° to 212° F)
Temperature Effect
- ± 2 % of Full Scale/50° F