Thermometer iTHERM ModuLine TM402

Brand: Endress+Hauser

Thermometer iTHERM ModuLine TM402

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Fundamental Fundamental

Specs at a Glance

Max. immersion length on request:
up to 15.5" (317,5mm)
others on request
Operating temperature range:
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static):
at 20 °C: 40 bar (580 psi)
Response time:
depending on configuration
Accuracy:
class A acc. to IEC 60751

Field of application

This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The input: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.

Features

  • International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability

Specifications

Industry

  • Food & Beverage
  • Other industries
  • Life Science

Product Family

  • iTHERM ModuLine

Thermometer

Characteristic / Application

  • imperial style
  • hygienic applications
  • aseptic applications
  • hygienic process connections
  • with neck

Thermowell / protection tube

  • without (direct immersion)

Insert / probe

  • without exchangeable insert

Outer diameter protection tube / Insert

  • 1/4'' (6,35 mm)
  • 3/8'' (9,53 mm)

Max. immersion length on request

  • up to 15.5" (317,5mm)
  • others on request

Material protection tube/ thermowell

  • 316L

Process connection

  • Triclamp
  • Clamp-connections according to ISO2852
  • G3/4" Liquiphant
  • G1" Liquiphant
  • Varivent

Tip shape

  • straight
  • reduced

Surface roughness Ra

  • 30 μin (0,76 μm)
  • 15 μin (0,38 μm)

Operating temperature range

  • PT100:
  • -50 °C … 200 °C
  • (-58 °F … 392 °F)

Max. process pressure (static)

  • at 20 °C: 40 bar (580 psi)

Accuracy

  • class A acc. to IEC 60751

Response time

  • depending on configuration

Integration head transmitter

  • yes (4 ... 20 mA, HART)

Certification

  • SIL (transmitter only)
show more