Accuracy
- 45 Hz to 500 Hz: 1.0 % + 3
- 500 Hz to 1 kHz: 2.0 % + 3
mV Specs
- Range: 600 mV
- Resolution: 0.1 mV
Overload Protection
- Fused, 44/100 A, 1000 V FAST Fuse
DC Functions
- ± 12 counts for changes > 350 mS in duration.
AC Functions
- ± 40 counts for changes > 900 mS in duration.
Electromagnetic Compatibility
- EN 61326-1:2006
- EN 61326-2-2:2006
- ETSI EN 300 328 V1.7.1:2006
- ETSI EN 300 489
- FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
- FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety Compliance
- ANSI / ISA 61010-1 / (82.02.01): 3rd edition
- CAN / CSA C22.2 No 61010-1-12: 3rd edition
- UL 61010-1: 3rd edition
- IEC / EN 61010-1:2010