8020 Insertion Flowmeter with Paddle Wheel

Brand: Burkert Fluid Control Systems

The paddle wheel flowmeter for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids. The Burkert designed fitting system ensures simple installation of the devices into all pipes from DN20 to DN400. 

The flowmeter produces a frequency pulse signal, proportional to the flow rate, which can easily be transmitted and processed by a Burkert transmitter/controller.

Features

  • Economic integration in pipe systems without any additional piping
  • 3-wire frequency pulse version to directly interface with PLC’s (both PNP and NPN)
  • Connection to Burkert devices in remote versions

Specifications

Non-Wetted Material

  • Housing: PE
  • Screw: Stainless Steel
  • Union Nut: PC
  • Female Cable Plug/Male Fixed Plug: Body, contact holder and cable gland in PA; Cable gland seal and flat seal in NBR

Wetted Material

  • Axis & Bearing: Ceramics
  • Paddle Wheel: PVDF
  • Sensor Armature: PVDF
  • Seal: FKM (EPDM as option)

Pipe Diameter

  • 3/8" to 16" (DN 20 to DN 400)

Measuring Range

  • Flow Rate: 0.5 to 75,000 l/min (0.13 to 19,813 gpm)
  • Flow Velocity: 0.3 to 10 m/s

Repeatability

  • ± 0.4 % of Reading

Measurement Deviation

  • Teach-in: ± 1 % of the Measured Value at Teach-in Flow Rate Value
  • Standard K Factor: ± 2.5 % of the Measured Value

Linearity

  • ± 0.5 % of Full Scale

Repeatability

  • ± 0.4 % of the Measured Value

Medium Temperature

  • PP: 0° to 80° C (32° to 176° F)
  • PVC: 0° to 50° C (32° to 122° F)
  • Stainless Steel, Brass, PVDF: -15° to 80° C (5° to 176° F)

Operating Voltage

  • 12-36 Vdc

Fluid Pressure

  • Max. PN 10

Approvals & Certifications

  • CE
  • PED

Ambient Temperature

  • Operating & Storage: -15° to 60° C (5° to 140° F)

Humidity

  • ≤ 80 % RH, Non-Condensing

Viscosity

  • 300 cSt, Max.

Environmental Protection

  • IP65

Electrical Connection

  • Female Cable Plug according to DIN EN 175301‑803
show more