TDLAS gas analyzer SS500

Brand: Endress+Hauser

TDLAS gas analyzer SS500

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Measured Variables:
Concentration
Dew Point
Cell Pressure
Cell Temperature
Measuring principle:
TDLAS
Hazardous area approvals:

CSA Class I, Division 2
CSA Class I, Zone 2

Field of application

Using patented tunable diode laser spectroscopy (TDLAS) technology, the SS500 analyzer is an economical choice for measuring H2O concentration in natural gas without coming into physical contact with the stream. The input is a sensor that does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, or amines.

Natural gas quality measurements in production, storage, transportation, and distribution

Monitoring for natural gas pipelines, processing plants, compressor stations, gathering sites, and distribution quality

Suitable for use as a check-measurement device

Measurable ranges of up to 0.25 – 100 lb/mmscf (5 – 2110 ppmv)​

Features

  • Economical real-time moisture measurements
  • Virtually maintenance-free
  • Reliable in harsh environments
  • Fast and accurate with no wet-up or dry-down delays
  • No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans
  • NIST-traceable calibration with analog and serial outputs for remote monitoring
  • CSA certified for CSA Class 1, Division 2 or Class 1, Division 1

Specifications

Industry

  • Oil & Gas

H2O

Product Headline

  • An economical gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Option of simplified sample conditioning to reduce complexity of the analyzer system.

Channels

  • 1

Analyte and Measurement ranges

  • H2O (Moisture):
  • 5 to 422 ppmv (minimum)
  • 5 to 2110 ppmv (maximum)

Measured Variables

  • Concentration
  • Dew Point
  • Cell Pressure
  • Cell Temperature

Ambient Temperature range

  • -20 to 50°C (-4 to 122°F)

Operating Pressure range

  • Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
  • Sample Cell: 700 to 1400 mbara

Analyzer Wetted materials

  • 316L stainless steel
  • FKM O-Rings
  • Glass

Power supply

  • 100 to 240 VAC, 50 to 60 Hz
  • or
  • 9 to 16 VDC or 18 to 32 VDC - optional
  • 1 Amp maximum at 120 VAC
  • 1.6 Amps at 24VDC, 3.2 Amps at 12 VDC

Communication

  • Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24 VDC max load
  • Serial: RS232C
  • Protocol: Modbus Gould RTU or Daniel RTU or ASCII
  • Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)

Housing materials

  • Electronics: 304 stainless steel (Class I Division 2)
  • Sample System Panel: anodized aluminum

Hazardous area approvals

  • CSA Class I, Division 2
  • CSA Class I, Zone 2

Degree of protection

  • Type 3R (Class I Division 2)
show more