Series DPT Digital Pressure Transmitter with Switch
Brand: Dwyer Instruments, LLCThe Series DPT Digital Pressure Transmitter with Switches combines a large, 14-segment LED display with two programmable solid state switches into one compact unit.
A unique, 3-way rotating design allows the DPT to meet specific installation requirements without any retrofitting. 
The display and electrical connection can be rotated independently to maximize visibility while still orienting the electrical connection in the best position for the cable connector.
Large, ergonomically designed push buttons allow for quick/easy programming and thin-film piezoresistive sensor technology guarantees long-term reliability and stability.
Features- Dual PNP solid state switches
 - 14-segment red LED display
 - User-friendly, intuitive 3-key operation
 - Rotating design: 330° display rotation; 180° display electronic rotation
 
Specifications
Accuracy
- ± 1 % of Full Scale (The Effect of Non-Linearity, Hysteresis, Zero Point are included)
 
Approvals & Certifications
- CE
 
Burst Pressure
- psig: 7,975 (kPa: 54,985, to bar: 549.85)
 
Consumption
- ≤ 100 mA
 
Display
- 4-digit LED: Red (0.35" H Digits)
 
Electrical Connectors
- M12 x 1, 5-Pin
 
Electrical Rating
- 250 mA
 
Enclosure, Body Material
- 316L Stainless Steel Lower Body
 - Fiberglass: Chemical Resistant Fiberglass Reinforced Plastic (PBT) Plastic Head
 
Environmental Protection
- IP67
 
Loop Resistance
- > 10 kΩ DPT-V
 - ≤ 0.5k ohms DPT-A
 
Maximum System Pressure
- psig: 1,740 (kPa: 11,996, bar: 119.96)
 
Media
- Gases
 - Liquids
 - Vapors
 
Mounting Position
- Any Orientation
 
NACE & NIST
- NIST Traceable Calibration Certificate
 
NPT Connection
- 1/4" NPT Male
 
Output
- 0-10 Vdc: DPT-V
 - 4-20 mA: DPT-A
 
Power Requirement
- 15-35 Vdc
 
Pressure Range
- bar: -1 to 68.9
 - kPa: -101.3 to 68,948
 - psig: -14.5 to 1,000
 
Switch Type
- PNP
 
Temperature Effect
- 0.2 % of Full Scale/10K
 
Temperature Range
- 0° to 80° C (32° to 176° F)
 
Wetted Materials
- 316L Stainless Steel Pressure Connection (13-8 PH for Ranges Above 150 psi)
 
- Calibration
 - Hydraulics and Pneumatics
 - Machine Tools
 - Compressors and Pumps
 - Machine Building