K2 Pressure Transducer with Millivolt Output

Brand: Ashcroft Inc
Does not ship to OH, United States

The Ashcroft K2 shares the same sensor platform as the model K1, except it is offered with a millivolt output option.

The all stainless steel CVD sensor design eliminates signal instability, drift, with excellent shock or vibration resistance. 

A perfect choice when long-term stability and high repeatability are needed.

Features
  • Pressure ranges from vacuum to 20,000 psi
  • ±0.50% or ±1.0% of span accuracy
  • Millivolt outputs
  • NEMA 4X ingress protection
  • All stainless steel wetted materials
  • Highly configurable – broad selection of pressure ranges, output signals, pressure connections and electrical terminations
  • CRN approved

Specifications

Brand

Reference Temperature

  • 68° F (20° C)

Accuracy

  • ± 1 % of Span
  • ± 0.5 % of Span

Stability

  • ± 0.5 % of Span/Year at reference conditions

Durability

  • > 10 Million Cycles

Best Fit Straight Line (BFSL)

  • ±0.25% or ±0.40% of Span

Pressure Range

  • Vacuum to 20,000 psi

Response Time

  • < 5 ms

Output

  • 2 mV/V
  • 3 mV/V
  • 10 mV/V
  • 20 mV/V

Wetted Material

  • Diaphragm: 17-4PH Stainless Steel
  • Process Connection: 304 Stainless Steel

Case Material

  • 300 Series Stainless Steel

Process Connection

  • 1/4" NPT Female
  • 9/16-18 Female Aminco®
  • 1/4" NPT Male
  • 1/8" NPT Male
  • 1/2" NPT Male
  • 7/16-20 SAE Male

Power Requirement

  • 5-10 Vdc Regulated
  • Voltage Output: < 3 mA

Position Effect

  • < 0.01 % of F.S.

Vibration Effect

  • < ± 0.1 % of Full Scale for 0 to 2000 Hz at 20g's in any axis

Shock Effect

  • < ± 0.05 % of Full Scale Effect for 100g's, 20 ms Shock in any Axis

Span & Zero Effect

  • 0.5% Accuracy: ± 0.028 % of Span/°F
  • 1% Accuracy: ± 0.04 % of Span/°F

Operating Temperature

  • -28° to 82° C (-20° to 180° F)

Compensated Temperature

  • -28° to 71° C (-20° to 160° F)

Storage Temperature

  • -54° to 121° C (-65° to 250° F)

Humidity

  • 95 % RH, Non-Condensing

Approvals & Certifications

  • CRN - Canadian Registration Number
  • UL

Environmental Rating

  • NEMA 4X (NEMA 1 only 500 psig if electrical termination is Bendix® (Ashcroft part codes B4 & B6)

  • Industrial and OEM Applications:
    • Machine Tool
    • Construction Equipment
    • Hydraulic & Pneumatic Systems
  • Process Applications:
    • Hydraulic
    • Refrigeration
    • HVAC
    • Pump Control

show more