The Ashcroft® PT-1 bench-top calibrator is used on measurement applications requiring highly accurate secondary transfer standards. 

The PT-1 includes 1 or 2 permanently installed pressure or temperature sensors.
Features
  • Simultaneously display the output of two pressure sensors, two RTD’s or one of each
  • 12 standard user selectable engineering units and one custom value
  • Dedicated front panel buttons to set zero, check maximum/minimum values, adjust measurement damping, select either or both ports for standard display, additive or differential display, print the display and configure the RS232 output
  • All front panel features are accessible via the RS232 port for remote configuration or data acquisition

Specifications

Accuracy

  • ± 0.025 % of Span
  • ± 0.05 % of Span
  • ± 0.1 % of Span

Approvals & Certifications

  • ISO 9001

Communication

  • RS-232

Compensated Temperature

  • -7° to 49° C (20° to 120° F)

Display

  • Backlit
  • Size: 16 Alphanumeric Character/Line, Max.
  • Size: 2 Line, 0.38” Height Per Line

Enclosure, Body Material

  • High Impact ABS, Black

Media

  • PPM1 Sensor Typical: Clean, Dry, Non-Conductive, Non-Corrosive Gas

NACE & NIST

  • NIST

NPT Inlet

  • 1/8” NPT Female

NPT Outlet

  • 1/8” NPT Female

Operating Temperature

  • 0° to 49° C (32° to 120° F)

Overpressure & Static Pressure Limits

  • 150 % for Ranges of psi: 1,500 (kPa: 10,340, bar: 103.4) & above
  • 200 % for Ranges of psi: 5 to 1,000 (kPa: 34.47 to 6,895, bar: 0.34 to 68.95)
  • Overpressure psi: -15 to 50 (-103.4 to 344.7, bar: -1 to 3.447)

Power Requirement

  • AC Adapter Provided for Operation Off Standard 110 Vdc, 60 Hz

Pressure Range

  • psi: 5 to 10,000 (kPa: 34.47 to 68,950, bar: 0.34 to 689.5)

Pressure Type

  • Absolute
  • Compound Pressure
  • Differential
  • Gauge (Sealed Gauge over 300 psi)
  • Vacuum

Repeatability

  • ± 0.01 % of Span (All psi Ranges, Ranges of 1” through 200” H₂O)
  • ± 0.02 % of Span (Ranges Below 1” H₂O)

Resolution

  • ± 0.002 % of Span, Max.

RTD Type

  • Pt100
  • Pt1000

Sensor, Probe Type

  • Platinum RTD

Storage Temperature

  • -20° to 70° C (-4° to 158° F)

Temperature Effect

  • Zero & Span: ± 0.004 % of Span/°F from a Reference Temperature of 70° ± 3° F

Update Time

  • Display Update: 100 milliseconds
  • Warm-Up: 30 minutes to Complete Stability
  • Warm-Up: 5 minutes to Rated Accuracy