Scale Ranges
- other units (e.g. psi, kPa) available or all other Equivalent vacuum or combined Pressure and vacuum Ranges
- 0 to 4 bar [0 to 58 psi] to 0 to 400 bar [0 to 5,802 psi]
Scale
- Option: Dual Scale
- Single scale
Pressure Limitation
- Short Time: Full Scale Value
- Fluctuating: 2/3 x Full Scale Value
- Steady: 3/4 x Full Scale Value
Connection Location
- Lower Back Mount
- Lower Mount (Radial)
Process Connection
- 1/8” NPT
- 1/4” NPT
- G 1/8” B
- G 1/4” B
Permissible Temperature
- Ambient: -20° to +60° C [-4° to 140° F]
- Medium: +100° C [+212° F] Max.
Temperature Effect
- When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.4 %/10 K of Full Scale Value
Case
- Safety version S3 per EN 837: with solid baffle wall (Solidfront) and blow-out back
Wetted Materials
- Process Connection, Pressure Element: 316L Stainless Steel, option: Monel (Model PGS26)
Non-Wetted Materials
- Option: Laminated Safety Glass
- Window Polycarbonate
- Set Pointer: Aluminium, Red
- Instrument Pointer: Aluminium, Black
- Dial: Aluminium, White, Black Lettering
- Case, movement, bayonet Ring: Stainless Steel
Ingress Protection Per IEC / EN 60529
Electrical Connection
- Cable length 2 m, facing downwards and to the right
- Material: PVC
- others on Request