Smartec CLD132
Brand: Endress+HauserSmartec CLD132
Brand: Endress+HauserSpecs at a Glance
Process pressure:
max. 12 bar (90°C)
(174 psi(194°F))
(174 psi(194°F))
Process temperature:
max. 140°C (max. 30 min.)
284°F (max. 30 min.)
284°F (max. 30 min.)
Measuring range:
100 µS/cm - 2000 mS/cm
Field of application
Smartec CLD132 is a measuring system for inductive conductivity. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a stainless steel temperature sensor that gives you an ultrafast temperature response for reliable measurement in separation applications.
Smartec CLD132 is suited to applications such as:
- Alkaline/acid concentration control in remaking
- Phase separation of product/water and product/product mixtures in pipe systems
- Product monitoring
- Smartec CLD132 features the following protocols and interfaces:
- 0/4...20mA
- HART
- PROFIBUS DP
- PROFIBUS PA
Features
- Engineered for quick temperature response
- Low risk of soiling due to encapsulated sensor
- Insensitive to polarization
Specifications
Brand
Industry
- Food & Beverage
- Other industries
Product Family
- Smartec
Conductivity
Application
- - Alkali/acid concentration control - phase separation in pipe systems - monitoring and control of bottle cleaning systems - product monitoring in breweries, dairies and the beverage industry - CIP system control
Characteristic
- Compact measuring system for an inductive conductivity measurement special made for media with a high conductivity.
Measuring range
- 100 µS/cm - 2000 mS/cm
Measuring principle
- Inductive measuring system including transmitter and sensor.
Design
- Compact transmitter made of stainless steel with an inductive sensor made of PEEK in a separate or compact version.
Material
- Housing: Stainless steel 1.4301 polished Window: Polycarbonate Sensor: PEEK, stainless steel 1.4435 Sealing: Chemraz
Process temperature
- max. 140°C (max. 30 min.)
- 284°F (max. 30 min.)
Process pressure
- max. 12 bar (90°C)
- (174 psi(194°F))
Temperature sensor
- Pt100
Ex certification
- No
Ingress protection
- IP67
Input
- One-channel transmitter incl. temperature.
Output / communication
- Conductivity and temperature 0/4-20 mA, HART, Profibus.