Model 532.53+8xx Absolute Pressure Gauge with Switch Contact

Brand: WIKA Alexander Wiegand SE & Co. KG

Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model 532.5x switchGAUGE finds its use.
Features
  • High overload safety, long service life due to metal media chamber sealing
  • Media chamber protected against unauthorised access
  • Also available with liquid-filled case for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications

Specifications

Design

  • Mechanical Absolute Pressure gauge per DIN 16002

Nominal Size in mm

  • 100
  • 160

Accuracy Class

  • 1.6 (Model 532.53)
  • Option:
  • 1.0 (Model 532.52)
  • 2.5 (Model 532.54)
  • The measurement accuracy is ensured for ambient Pressure fluctuations between 955 and 1,065 mbar (Min. and Max. of atmospheric Pressure)

Scale Ranges

  • 0 to 25 mbar 2) to 0 to 25 bar Absolute Pressure [0 to 0.36 psi to 0 to 3,600 psi Absolute Pressure]

Scale

  • Single scale
  • Option: Dual Scale

Pressure Limitation

  • Steady: Full Scale Value
  • Fluctuating: 0.9 x Full Scale Value

Overload Safety

  • 10 x Full Scale Value, Max. 25 bar Absolute Pressure, min. 1 bar Absolute Pressure
  • Option: 20 x Full Scale Value, Max. 25 bar Absolute Pressure, min. 1 bar Absolute Pressure

Process Connection with Lower Measuring Flange

  • Small Flange for vacuum applications DN 10
  • Small Flange for vacuum applications DN 16
  • Open Connecting Flange DN 25 PN 25, DIN 2501, Form D per DIN 2526
  • Open Connecting Flange DN 25 PN 25 per EN 1092-1, Form B
  • 1/2” NPT Female
  • 1/2” NPT
  • G 1/2 B

Permissible Temperature

  • Medium: +100° C [+212° F] Max.
  • Option: +200° C [+392° F] Max.
  • Ambient: -20° to +60° C [-4° to 140° F]
  • Option: -40° to +60° C (Silicone oil filling) ¹⁾

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.8 %/10 K of Full Scale Value

Case

  • Option: Safety version S3 per EN 837: with solid baffle wall (Solidfront) and blow-out back (Models 532.32
  • 532.33, 532.34)
  • Instruments with liquid filling with compensating valve to vent case
  • Version S1 per EN 837: with blow-out device in Case back

Case Filling

  • Without
  • Option: with Silicone oil M50 Case filling, ingress Protection IP65 (Models 533.52, 533.53, 533.54)

Wetted Materials

  • Diaphragm Element (Pressure Element), ≤ 0.25 bar: Stainless Steel 316Ti, > 0.25 bar: NiCr Alloy (Inconel)
  • Media chamber with process Connection: 316L Stainless Steel
  • Option: Wetted Parts from Monel (Models 56x.3x, 56x.5x)

  • Control and regulation of processes
  • Monitoring of plants and switching of circuits
  • Pressure measurement independent of fluctuations in the atmospheric pressure
  • Monitoring of vacuum pumps, packaging machines and condensation pressures, determination of vapour pressure in liquids

show more