Specs at a Glance

Measuring cell:
400 mbar...400 bar
(6psi...6,000psi)
Accuracy:
Standard:
up to 0.075 %
Platinum
up to 0.055 %
Pressure measuring range:
400 mbar... 400 bar
(6psi...6,000psi)
Material process membrane:
316L, AlloyC,
Tantal, Monel,
PTFE
Process temperature:
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C...+400°C
(-40°F...+752°F)
Main wetted parts:
316L, AlloyC,
Tantal, Monel,
PTFE

Field of application

The Cerabar PMP51B is a pressure transmitter with metal membrane for highly accurate measurement of liquids and gases. It offers easy local or remote operation and condition-based maintenance which promotes better management of scheduled plant shutdowns.

Specifications

Product Family

  • Cerabar

Continuous / Liquids

Characteristic / Application

  • Pressure transmitter with metal membrane for accurate measurement in liquids or gases.
  • Available with diaphragm seals.
  • Intuitive and clear wizard for commissioning

Specialities

  • Bluetooth® Operation and maintenance SmartBlue App,
  • RFID TAG for easy identification,
  • Plug and play functionalities

Supply / Communication

  • Ex d, Ex e, non-Ex:
  • 10.5...35V DC
  • Ex i: 10.5...30V DC

Accuracy

  • Standard:
  • up to 0.075 %
  • Platinum
  • up to 0.055 %

Long term stability

  • 0.1 % of URL/ year
  • 0.2 % of URL/ 5 years
  • 0.25 % of URL/ 10 years

Ambient temperature

  • -40°C...+85°C
  • (-40°F...+185°F)

Process temperature

  • Standard:
  • -40°C…+125°C
  • (-40°F…+257°F)
  • Diaphragm seal:
  • -40°C...+400°C
  • (-40°F...+752°F)

Process pressure / max. overpressure limit

  • 700 bar (10,500 psi)

Pressure measuring range

  • 400 mbar... 400 bar
  • (6psi...6,000psi)

Main wetted parts

  • 316L, AlloyC,
  • Tantal, Monel,
  • PTFE

Process connection

  • Thread:
  • G1/2...G2, R1/2, MNPT3/4...MNPT2,
  • FNPT1/2
  • Flange:
  • DN25...DN80,
  • NPS 1"...3"

Max. measurement distance

  • 4000 m (13,123 ft) H2O

Communication

  • 4...20 mA,
  • 4...20 mA HART
  • PROFINET with Ethernet-APL
  • Bluetooth® wireless
  • technology and app (optional)

Certificates / Approvals

  • ATEX, IEC Ex, CSA C/US, NEPSI

Safety approvals

  • SIL

Design approvals

  • EN 10204-3.1
  • NACE MR0175,
  • NACE MR0103,
  • AD2000

Hygienic approvals

  • Hygienic approvals

Marine approval

  • Marine approval

Drinking water approvals

  • NSF

Options

  • Diaphragm seal

Application limits

  • Measuring cell: Metal welded
  • If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure: hydrostatic pressure

Pressure

Characteristic

  • Pressure transmitter with metal membrane for accurate measurement in liquids or gases.
  • Available with diaphragm seals.
  • Intuitive and clear wizard for commissioning

Supply voltage

  • Ex d, Ex e, non-Ex:
  • 10.5...35V DC
  • Ex i: 10.5...30V DC

Reference Accuracy

  • Standard:
  • up to 0.075 %
  • Platinum:
  • up to 0.055 %

Long term stability

  • 0.1% of URL/year
  • 0.2% of URL/ 5 years
  • 0.25% of URL/ 10 years

Process temperature

  • Standard:
  • -40°C…+125°C
  • (-40°F…+257°F)
  • Diaphragm seal:
  • -70°C...+400°C
  • (-x°F...+752°F)

Ambient temperature

  • -40°C...+85°C
  • (-40°F...+185°F)

Measuring cell

  • 400 mbar...400 bar
  • (6psi...6,000psi)

Smallest calibratable span

  • 20 mbar (0.3 psi)

Vacuum resistance

  • 50 mbar (0.725 psi)

Max. Turn down

  • 100:1

Max. overpressure limit

  • 2,800 bar (40,600 psi)

Process connection

  • Thread:
  • G1/2...G2, R1/2, MNPT3/4...MNPT2,
  • FNPT1/2
  • Flange:
  • DN25...DN80,
  • NPS 1"...3"

Process connection hygienic

  • Process connection hygienic

Material process membrane

  • 316L, AlloyC,
  • Tantal, Monel,
  • PTFE

Material gasket

  • PTFE

Fill fluid

  • Silicone oil, Inert oil,
  • Vegetable oil,
  • High/ low temperature oil

Material housing

  • Aluminium

Communication

  • 4...20 mA,
  • 4...20 mA HART
  • PROFINET with Ethernet-APL
  • Bluetooth® wireless
  • technology and app (optional)

Certificates / Approvals

  • ATEX, IEC Ex, CSA C/US, NEPSI

Safety approvals

  • SIL

Design approvals

  • EN10204-3.1,
  • NACE MR0175,
  • NACE MR0103

Hygienic approvals

  • Hygienic approvals

Marine approvals

  • Marine approvals

Drinking water approvals

  • NSF

Specialities

  • Bluetooth® Operation and maintenance SmartBlue App,
  • RFID TAG for easy identification,
  • Plug and play functionalities
show more