Specs at a Glance

Max. immersion length on request:
up to 100" (2540 mm)
others on request
Max. process pressure (static):
Not applicable
Response time:
63% rt = 3 s
Operating temperature range:
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Accuracy:
class A acc. to IEC 60751
class B acc. to IEC 60751

Field of application

The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.

Features

  • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
  • All iTEMP transmitters provide long term stability ≤0.05% per year
  • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications

Specifications

Industry

  • Chemical
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Other industries

Product Family

  • iTHERM ModuLine

Thermometer

Characteristic / Application

  • Explosion Proof US style
  • modular temperature assembly
  • for heavy duty applications
  • with extension
  • to be used with existing thermowell

Thermowell / protection tube

  • to be used with thermowell

Insert / probe

  • mineral insulated (MI), flexible
  • PTFE-insulated, rigid

Outer diameter protection tube / Insert

  • Not applicable

Max. immersion length on request

  • up to 100" (2540 mm)
  • others on request

Material protection tube/ thermowell

  • Sensor sheath
  • 316/316L

Optional coating

  • Not defined

Process connection

  • male thread:
  • NPT1/2"

Tip shape

  • straight

Surface roughness Ra

  • Not defined

Operating temperature range

  • PT100 WW:
  • -200 °C … 600 °C
  • (-328 °F … 1.112 °F)
  • PT100 TF:
  • -50 °C … 200 °C
  • (-58 °F … 392 °F)

Max. process pressure (static)

  • Not applicable

Accuracy

  • class A acc. to IEC 60751
  • class B acc. to IEC 60751

Response time

  • 63% rt = 3 s

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

  • FM XP DIP
  • FM XP NI DIP
  • CSA XP DIP
  • CSA XP NI DIP
  • FM/CSA XP DIP
  • FM/CSA XP NI DIP
  • CSA C/US XP, DIP
  • cCSAus General Purpose

Certification

  • SIL (transmitter only)