Heavy duty (old thermometer line) T15
Brand: Endress+HauserHeavy duty (old thermometer line) T15
Brand: Endress+Hauser
Extended Specs at a Glance
Max. immersion length on request:
up to 100" (2540 mm)
others on request
others on request
Max. process pressure (static):
Not applicable
Response time:
63% rt = 3 s
Operating temperature range:
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Accuracy:
class A acc. to IEC 60751
class B acc. to IEC 60751
class B acc. to IEC 60751
Field of application
The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
Features
- FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
- All iTEMP transmitters provide long term stability ≤0.05% per year
- One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
Specifications
Brand
Industry
- Chemical
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Other industries
Product Family
- iTHERM ModuLine
Thermometer
Characteristic / Application
- Explosion Proof US style
- modular temperature assembly
- for heavy duty applications
- with extension
- to be used with existing thermowell
Thermowell / protection tube
- to be used with thermowell
Insert / probe
- mineral insulated (MI), flexible
- PTFE-insulated, rigid
Outer diameter protection tube / Insert
- Not applicable
Max. immersion length on request
- up to 100" (2540 mm)
- others on request
Material protection tube/ thermowell
- Sensor sheath
- 316/316L
Optional coating
- Not defined
Process connection
- male thread:
- NPT1/2"
Tip shape
- straight
Surface roughness Ra
- Not defined
Operating temperature range
- PT100 WW:
- -200 °C … 600 °C
- (-328 °F … 1.112 °F)
- PT100 TF:
- -50 °C … 200 °C
- (-58 °F … 392 °F)
Max. process pressure (static)
- Not applicable
Accuracy
- class A acc. to IEC 60751
- class B acc. to IEC 60751
Response time
- 63% rt = 3 s
Integration head transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
- FM XP DIP
- FM XP NI DIP
- CSA XP DIP
- CSA XP NI DIP
- FM/CSA XP DIP
- FM/CSA XP NI DIP
- CSA C/US XP, DIP
- cCSAus General Purpose
Certification
- SIL (transmitter only)