Model VT-300 Miniature Vane Thermo-Anemometer

Brand: Dwyer Instruments, LLC

The Model VT-300 Miniature Vane Thermo-Anemometer measures air velocity, air volume, temperature, and humidity inside air ducts.

This meter includes a telescoping vane probe that is only 0.7˝ (18 mm) in diameter that allows duct traverse measurements up to 20˝ ducts. User-selectable units include ft/min, m/s, knots, mph, and km/hr. 

The vane probe has a built-in sensor to record temperature in °F or °C, as well as humidity in %RH. There are three modes which include viewing data in real time, manual recording, and automatic recording. 

Model VT-300 can store measurements that can later be transferred to a PC via RS-232 communication. The vane probe is detachable for easy replacement, if necessary, or as an addition to Model 9671.

Each unit is supplied with a hard carrying case, batteries, logging software CD, USB to RS-232 cable and Instruction Manual.
Features
  • 3-in-1 parameters: Air Velocity/Flow, RH, and Temperature
  • Telescopic probe for traversing ducts up to 20”
  • Built-in data logging for paperless reporting
  • Vane Anemometer offers wider application use vs pitot or hotwire
  • Hard case, Batteries, and software included

Specifications

Accuracy

  • ± 0.6° C (± 1° F) from -20° to 50° C (-4° to 122° F) - Temperature Range
  • ± 1.2° C (± 2.2° F) from 50° to 60° C (122° to 140° F) - Temperture Range
  • ± 3 % of Reading + 0.2 m/sec - Air Velocity
  • ± 3 % Relative Humidity at 25° C (10 to 90 % Relative Humidity)
  • ± 5 % Relative Humidity (0.1 to 10 % Relative Humidity, 90 to 99.9 % Relative Humidity)

Approvals & Certifications

  • CE

Display

  • 1 x 1.8˝ (26 x 45 mm)

Flow Capacity

  • 0 to 99,999 cfm

Flow Rate

  • Air: 98.4 to 3937 fpm (0.5 to 20 mps)

Humidity

  • < 80 % Relative Humidity - Operating
  • < 90 % Relative Humidity - Storage
  • 0.1 to 99.9 % Relative Humidity
  • 10 to 90 % Relative Humidity
  • 90 to 99.9 % Relative Humidity

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Power Requirement

  • 1.5 V - Alkaline Batteries

Resolution

  • 0.1 m/sec - Air Velocity
  • 0.1 % Relative Humidity
  • 0.1° C (0.1° F) - Temperature
  • 0.1° C (0.1° F) - Wet Bulb

Response Time

  • 1 Minute - Relative Humidity
  • 1 Minute - Temperture
  • 1 second - Air Velocity

Sensor / Probe Diameter

  • 0.7” (18 mm) - Vane Diameter

Storage Temperature

  • -20° to 50° C (-4° to 122° F)

Temperature Range

  • -22° to 70° C (-7.6° to 158° F)

  • Building commissioning
  • Building HVAC test and balance
  • Critical environment testing
  • Industrial process verification
  • Instrumentation validation
show more