Thermometer Industrial RTD assemblies TH15

Brand: Endress+Hauser

Thermometer Industrial RTD assemblies TH15

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Accuracy:
class A acc. to IEC 60751
class B acc. to IEC 60751
Operating temperature range:
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static):
class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751
Max. immersion length on request:
up to 41" (1041 mm)
others on request

Field of application

Product being phased out, limited
availability.
Spring loaded temperature measuring
device, without thermowell.
Pt100 sensor comply with IEC60751
standard, alpha=0.00385.

Specifications

Industry

  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)
  • Other industries

Thermometer

Characteristic / Application

  • Industrial US style
  • modular temperature assembly
  • with extension
  • to be used with existing thermowell

Thermowell / protection tube

  • to be used with thermowell

Insert / probe

  • mineral insulated (MI), flexible
  • PTFE-insulated, rigid

Outer diameter protection tube / Insert

  • Insert 1/4'' (6,35 mm)

Max. immersion length on request

  • up to 41" (1041 mm)
  • others on request

Material protection tube/ thermowell

  • Sensor sheath
  • 316/316L

Optional coating

  • Not applicable

Process connection

  • Schutzrohranschluss
  • Außen-Gewinde:
  • NPT1/2"
  • 1-1/4"-18 UNEF

Tip shape

  • straight

Surface roughness Ra

  • Not defined

Operating temperature range

  • PT100 WW:
  • -200 °C … 600 °C
  • (-328 °F … 1.112 °F)
  • iTHERM StrongSens:
  • -50 °C … 500 °C
  • (-58 °F … 932 °F)
  • PT100 TF:
  • -50 °C … 200 °C
  • (-58 °F … 392 °F)

Max. process pressure (static)

  • class AA acc. to IEC 60751
  • class A acc. to IEC 60751
  • class B acc. to IEC 60751

Accuracy

  • class A acc. to IEC 60751
  • class B acc. to IEC 60751

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

  • transmitter only
  • FM IS
  • CSA IS
  • FM/CSA IS

Certification

  • SIL (transmitter only)

Documentation

show more