Thermometer Industrial RTD assemblies TH15
Brand: Endress+HauserThermometer Industrial RTD assemblies TH15
Brand: Endress+Hauser
Extended Specs at a Glance
Accuracy:
class A acc. to IEC 60751
class B acc. to IEC 60751
class B acc. to IEC 60751
Operating temperature range:
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static):
class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751
Max. immersion length on request:
up to 41" (1041 mm)
others on request
others on request
Field of application
Product being phased out, limited
availability.
Spring loaded temperature measuring
device, without thermowell.
Pt100 sensor comply with IEC60751
standard, alpha=0.00385.
Specifications
Brand
Industry
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Pulp & Paper (incl. Printing)
- Other industries
Thermometer
Characteristic / Application
- Industrial US style
- modular temperature assembly
- with extension
- to be used with existing thermowell
Thermowell / protection tube
- to be used with thermowell
Insert / probe
- mineral insulated (MI), flexible
- PTFE-insulated, rigid
Outer diameter protection tube / Insert
- Insert 1/4'' (6,35 mm)
Max. immersion length on request
- up to 41" (1041 mm)
- others on request
Material protection tube/ thermowell
- Sensor sheath
- 316/316L
Optional coating
- Not applicable
Process connection
- Schutzrohranschluss
- Außen-Gewinde:
- NPT1/2"
- 1-1/4"-18 UNEF
Tip shape
- straight
Surface roughness Ra
- Not defined
Operating temperature range
- PT100 WW:
- -200 °C … 600 °C
- (-328 °F … 1.112 °F)
- iTHERM StrongSens:
- -50 °C … 500 °C
- (-58 °F … 932 °F)
- PT100 TF:
- -50 °C … 200 °C
- (-58 °F … 392 °F)
Max. process pressure (static)
- class AA acc. to IEC 60751
- class A acc. to IEC 60751
- class B acc. to IEC 60751
Accuracy
- class A acc. to IEC 60751
- class B acc. to IEC 60751
Integration head transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
- transmitter only
- FM IS
- CSA IS
- FM/CSA IS
Certification
- SIL (transmitter only)