Memosens CLS82E

Brand: Endress+Hauser

Memosens CLS82E

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Process pressure:
17 bar abs at 20 °C (247 psi at 68 °F)
9 bar abs at 120 °C (131 psi at 248 °F)
Process temperature:
-5 to 120 °C (23 to 248 °F)
Sterilization: max. 140 °C at 6 bar for max. 45 min
(Max. 284 °F at 87 psi for max. 45 min)
Measurement range:
1 µS/cm to 500 mS/cm

Field of application

The Memosens CLS82E is a high-end, hygienic sensor for applications with widely varying conductivity values. It enables reliable monitoring of core processes as well as final rinse with only one sensor. FDA compliance and a small, compact design ensure the perfect fit to your processes. With Memosens 2.0 digital technology, CLS82E allows for extended storage of process and sensor data facilitating lab calibration and predictive maintenance and providing the perfect basis for enhanced IIoT services.

Specifications

Product Family

  • Memosens

Conductivity

Application

  • Phase seperation, chromotography, fermentation
  • CIP monitoring in small pipes
  • Ultrafiltration
  • Final rinse

Characteristic

  • Conductivity sensor with a broad measurement range for all hygienic applications with advanced requirements to process safety

Measurement range

  • 1 µS/cm to 500 mS/cm

Measuring principle

  • Hygienic 4-electrode conductivity sensor

Design

  • Certified hygienic design with FDA compliant materials, 3-A and EHEDG certified, available as 120 mm sensor with PG13.5 and in many other standard process connections

Material

  • Process connection: stainless steel 1.4435 (316L)
  • Sensor element: platinum and ceramic

Dimension

  • Sensor diameter: 12 mm (0.47 inch)
  • Electrode length: depending on process connection

Process temperature

  • -5 to 120 °C (23 to 248 °F)
  • Sterilization: max. 140 °C at 6 bar for max. 45 min
  • (Max. 284 °F at 87 psi for max. 45 min)

Process pressure

  • 17 bar abs at 20 °C (247 psi at 68 °F)
  • 9 bar abs at 120 °C (131 psi at 248 °F)

Temperature sensor

  • Pt1000

Ex certification

  • ATEX, NEPSI, CSA, IECE, EAC Ex, INMETRO

Connection

  • Clamp 1,5", Clamp 2", Varivent F DN25,Varivent N DN40-DN125, BioControl DN25, PG13,5, DN25 standard/40mm, DN25 B.Braun port/65mm, Threat G1", Thread NPT 1"
  • Sensor connection: Inductive, digital connection head with Memosens 2.0 technology

Ingress protection

  • IP 68 / NEMA Type 6P

Additional certifications

  • Material certification 3.1
  • 3-A and EHEDG certified, hygienic design
  • ASME BPE
  • Conformity to cGMP derived requirements
  • FDA approved
  • Regulation (EC) No. 1935/2004
  • China Food
show more