Certifications & Approvals
Measuring Range
- TRS: 0 to 70 ppm (GM32 TRS-PE System)
- (CH3)2S2: 0 to 15 ppm (GM32 TRS-PE System)
- (CH3)2S: 0 to 20 ppm (GM32 TRS-PE System)
- CH3SH: 0 to 25 ppm (GM32 TRS-PE System)
- H₂S: 0 to 35 ppm (GM32 TRS-PE System)
- NH₃: 0 to 35 ppm / 0 to 50 ppm (GM32 TRS-PE System), 0 to 30 ppm / 0 to 2,600 ppm (GM32 System, Standard and Ex-version)
- SO₂: 0 to 32 ppm / 0 to 7,000 ppm (GM32 System, Standard and Ex-version), 0 to 15 ppm / 0 to 35 ppm (GM32 TRS-PE System)
- Low NO₂: 0 to 20 ppm / 0 to 1,000 ppm
- NO₂: 0 to 50 ppm / 0 to 1,000 ppm
- NO: 0 to 40 ppm / 0 to 1,900 ppm (GM32 System, Standard and Ex-version), 0 to 40 ppm / 0 to 150 ppm (GM32 TRS-PE System)
Response Time
- Cross-duct Version: ≥ 5 s
- Gas-testable Measuring Probe (GPP): ≥ 120 s
- Open Measuring Probe (GMP): ≥ 5 s
Accuracy
- 1 % (Gas-testable Measuring Probe (GPP))
- SO₂ ± 0.3 ppm, ± 2 % (GM32 TRS-PE System)
- ± 2 %
Ambient/Storage Temperature
- -20° to 55° C, Temperature Change Max. ± 10° C/h
Humidity
- Ambient: ≤ 95 % Relative Humidity, Non-Condensing
Mounting
- Mounting Flange, ANSI, 5″
- Mounting Flange, DN 125, PN 6
Materials of Construction
- Ceramics
- Stainless Steel 1.4539
- Stainless Steel 1.4571
- PTFE
- Steel ST37