iTHERM ModuLine TM152

Brand: Endress+Hauser

iTHERM ModuLine TM152

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Response time:
depending on configuration
Max. process pressure (static):
depending on the configuration up to 500 bar
Accuracy:
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Operating temperature range:
PT100 TF iTHERM StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 TF iTHERM QuickSens:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 basic TF:
-50 °C ...200 °C
(-58 °F ...392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. immersion length on request:
84"

Field of application

The modular industrial RTD or TC thermometer iTHERM ModuLine TM152 is complete with barstock thermowell or to be used with onsite thermowell. It is suitable for every application, from basic functionality to high-end performance in the chemical, oil & gas and power & energy industries.

For universal use

Measuring range: –200 to +1 100 °C (–328 to +2 012 °F)

Pressure range: up to 500 bar (7 252 psi)

Features

  • Easy maintenance and recalibration of the thermometer (sensor can be replaced without interrupting the process)
  • Dual Seal technology: second process seal with failure indication offers valuable device health status information
  • iTHERM QuickSens: fastest response times of 1.5 s for optimum process control
  • iTHERM StrongSens: unsurpassed vibration resistance (>60g) for ultimate plant safety
  • iTHERM QuickNeck: cost and time savings thanks to simple, tool-free removal for recalibration
  • International certification: e.g. explosion protection in accordance with ATEX, IECEx, CSA and INMETRO; functional safety (SIL)
  • iTEMP temperature transmitter with all common communication protocols and optional Bluetooth® connectivity

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Power & Energy
  • Oil & Gas
  • Other industries

Product Family

  • iTHERM ModuLine

Thermometer

Characteristic / Application

  • imperial style
  • modular temperature assembly
  • universal range of application
  • suitable for hazardous areas
  • suitable for high process pressures
  • with neck or iTHERM QuickNeck
  • incl. thermowell / protection tube (metal) or to be installed into thermowell
  • can be used with iTHERM StrongSens

Thermowell / protection tube

  • barstock (drilled) or to be used with thermowell

Insert / probe

  • mineral insulated (MI), flexible

Outer diameter protection tube / Insert

  • 5/8" (15.88 mm)
  • 3/4" (19.05 mm)
  • 7/8" (22.2 mm)
  • 1" (25.4 mm)
  • 1.050" (26.7 mm)
  • 1-1/16" (27 mm)
  • 1-1/8" (28.58 mm)
  • 1-1/4" (31.75 mm)
  • 1.315" (33.4 mm)
  • 1-3/8" (34.93 mm)
  • 1-1/2" (38.1 mm)
  • 1.660" (42.16 mm)
  • 1.900" (48.26 mm)

Max. immersion length on request

  • 84"

Material protection tube/ thermowell

  • 316/316L
  • 304/304L
  • Alloy600
  • AlloyC276
  • A182 F22
  • A182 F11
  • A182 F91
  • A105
  • Duplex

Optional coating

  • PTFE coated
  • Tantalum sleeve

Process connection

  • Male thread:
  • G1/2", G3/4"
  • NPT1/2", NPT3/4", NPT 1", NPT 1-1/4", NPT 1-1/2"
  • Innen-Gewinde:
  • NPT1/2"
  • Flansche:
  • ASME 1" 150 RF
  • ASME 1" 300 RF
  • ASME 1" 600 RF
  • ASME 1" 900/1500 RF
  • ASME 1 1/2" 150 RF
  • ASME 1 1/2" 300 RF
  • ASME 1 1/2" 600 RF
  • ASME 1 1/2" 900/1500 RF
  • ASME 2" 150 RF
  • ASME 2" 300 RF
  • ASME 2" 600 RF
  • zum Einschweißen:
  • NPS 3/4" (26.7 mm)
  • NPS 1" (33.4 mm)
  • NPS 1-1/4" (42.2 mm)
  • NPS 1-1/2" (48.3 mm)
  • 1-3/8" (34.92 mm)

Tip shape

  • straight
  • tapered
  • stepped

Surface roughness Ra

  • 0,76 μm (30 μin.)
  • 1,6 μm (63,0 μin.)

Operating temperature range

  • PT100 TF iTHERM StrongSens:
  • -50 °C ...500 °C
  • (-58 °F ...932 °F)
  • PT100 TF iTHERM QuickSens:
  • -50 °C …200 °C
  • (-58 °F …392 °F)
  • PT100 WW:
  • -200 °C ...600 °C
  • (-328 °F ...1.112 °F)
  • PT100 basic TF:
  • -50 °C ...200 °C
  • (-58 °F ...392 °F)
  • Typ K:
  • max. 1.100 °C
  • (max. 2.012 °F)
  • Typ J:
  • max. 800 °C
  • (max. 1.472 °F)
  • Typ N:

Max. process pressure (static)

  • depending on the configuration up to 500 bar

Accuracy

  • Class AA acc. to IEC 60751
  • Class A acc. to IEC 60751
  • Class B acc. to IEC 60751
  • Class special or standard acc. to ASTM E230
  • Class 1 or 2 acc. to IEC 60584-2

Response time

  • depending on configuration

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

  • ATEX Ex ec
  • ATEX IECEx Ex ia
  • CSA C/US IS, NI, XP, DIP
  • INMETRO Ex ia

Certification

  • SIL (Transmitter), CRN
show more