Accuracy
- ± 0.125 % of Full Scale BFSL
- ± 0.25 % of Full Scale BFSL
Applications
- Irrigation
- Tank Monitoring
- Water & Wastewater
- Wellhead Monitoring
Approvals & Certifications
- CE Compliant to Suppress RFI, EMI & ESD
Compensated Temperature
- 0° to 50° C (32° to 122° F)
Electrical Connectors
- FEP Cable
- Standard Polyurethane (PUR) Cable
- Water-BLocked PVC Cable (200+ psi Only)
Electrical Protection
- Optional Lightning Protection Per EN 6100-4-5, 1.5J
- Reverse Polarity
- Short Circuit
Load Limit
- ≤ (VPower-10) / 0.020 Amp for 4-20 mA
- ≥ 10,000 ohms for 0-10 Vdc, 3-Wire
- ≥ 5,000 ohms for 0-5 Vdc, 3-Wire
NPT Connection
- 1/2” NPT Male
- 1/4” NPT Female
Options
- Cable Clamp
- Cable Junction Box
- Desiccant Cartridge
- Filter Element
- Lightning Protection
- Pt100 RTD
Output
- 0.5-2.5 Vdc, 3-Wire
- 0-10 Vdc, 3-Wire
- 0-5 Vdc, 3-Wire
- 4-20 mA, 2-Wire
Power Requirement
- 10-30 Vdc (4-20 mA, 2-Wire, 0-5 Vdc, 3-Wire)
- 14-30 Vdc (0-10 Vdc, 3-Wire)
- 5-30 Vdc (0.5-2.5 Vdc, 3-Wire)
Pressure Range
- bar: 0 to 68.9
- Inches WC: 0 to 400
- kPa: 0 to 6,895
- psig: 0 to 1,000
Process Temperature
- -10° to 50° C (14° to 122° F)
Response Time
- ≤ 1 milliseconds (Between 10 % & 90 % of Full Scale)
Shock
- 100 G as Per IEC 60068-2-27
Stability
- ≤ ± 0.2 % of Full Scale for 1-Year, Non-Accumulating
Storage Temperature
- -30° to 80° C (-22° to 176° F)
Vibration
- 15 G as Per IEC 60068-2-6
Wetted Materials
- 316 Stainless Steel with Weighted Nose Cone (Measuring Element)