Nominal Size
- Nominal Size 6” (160 mm) for level indicator
Accuracy Class (± 2.5 % of Full Span)
DP Ranges
- Measuring Cell 1605 inWC (4000 mbar): Adj. Span 0…461 inWC to 0…1605 inWC
- Measuring Cell 923 inWC (2300 mbar): Adj. Span 0…260 inWC to 0…923 inWC
- Measuring Cell 453 inWC (1130 mbar): Adj. Span 0…128 inWC to 0…453 inWC
- Measuring Cell 224 inWC (560 mbar): Adj. Span 0…64 inWC to 0…224 inWC
- Measuring Cell 112 inWC (280 mbar): Adj. Span 0…32 inWC to 0…112 inWC
- Measuring Cell 56 inWC (140 mbar): Adj. Span 0…16 inWC to 0…56 inWC
Overpressure Safety
- 725 psi (50 bar) Either Side
Maximum Ambient Temperature Range
- -40…+176° F (-40…+80° C), -40…+140° F (-40…+60° C) for oxygen Service
Maximum Media Temperature Range
- -40…+176° F (-40…+80° C), -40…+140° F (-40…+60° C) for oxygen Service
Measuring Cell Flanges (Wetted)
- v
- Model 712.15: Copper Alloy CW614N (CuZn39Pb3)
Pressure Elements (Wetted)
- Separating Diaphragm, NBR
- Transmission Parts, Stainless Steel 1.4301 and 1.4305
- Compression spring, Stainless Steel 1.4310
Movement
- Wear Parts Stainless Steel
Pointer
- Adjustable Pointer, Black Aluminum
Case & Bezel
- 304 Stainless Steel, slip-On, secured with clips