Nominal Size
- Nominal Size 6" (160 mm) for level indicator
Accuracy Class (± 2.5 % of Full Span)
DP Ranges
- Measuring Cell 1605 inH₂O (4000 mbar): Adj. Span 0…461 inH₂O to 0…1605 inH₂O
- Measuring Cell 923 inH₂O (2300 mbar): Adj. Span 0…260 inH₂O to 0…923 inH₂O
- Measuring Cell 453 inH₂O (1130 mbar): Adj. Span 0…128 inH₂O to 0…453 inH₂O
- Measuring Cell 224 inH₂O (560 mbar): Adj. Span 0…64 inH₂O to 0…224 inH₂O
- Measuring Cell 112 inH₂O (280 mbar): Adj. Span 0…32 inH₂O to 0…112 inH₂O
- Measuring Cell 56 inH₂O (140 mbar): Adj. Span 0…16 inH₂O to 0…56 inH₂O
Overpressure Safety
- 725 psi (50 bar) Either Side
Maximum Ambient Temperature Range
- -40 to +176° F (-40 to +80° C), -40 to +140° F (-40 to +60° C) for oxygen Service
Maximum Media Temperature Range
- -40 to +176° F (-40 to +80° C), -40 to +140° F (-40 to +60° C) for oxygen Service
Measuring Cell Flanges (Wetted)
- v
- Model 712.15: Copper Alloy CW 614N (CuZn₃₉Pb3)
Pressure Elements (Wetted)
- Separating Diaphragm, NBR
- Transmission Parts, Stainless Steel 1.4301 and 1.4305
- Compression spring, Stainless Steel 1.4310
Movement
- Wear Parts Stainless Steel
Pointer
- Adjustable Pointer, Black Aluminum
Case & Bezel
- 304 Stainless Steel, slip-On, secured with clips