Power Supply
- The Power Supply depends on the selected output signal
- DC 0.5 ... 4.5 V: DC 4.5 ... 5.5 V
- DC 0 ... 10 V: DC 14 ... 30 V
- DC 1 ... 5 V: DC 8 ...30 V
- 4 ... 20 mA: DC 7 ...30 V
Temperature
- 59° to 77° F (15° to 25° C)
Atmospheric Pressure
- 12.5 ... 15.4 psi (860 ... 1,060 mbar)
Nominal Position
- Calibrated in vertical Mounting position with process Connection facing downwards.
Accuracy at Reference Conditions
- Including Non-linearity, hysteresis, zero offset and end value deviation (Corresponds to measured error per IEC 61298-2).
- ≤ 2 % of Span
Temperature Error at -13 ... 185° F (-25 ... +85° C)
- Mean Temperature coefficient of Span: ≤ 0.3 % of Span/10 K
- Mean Temperature coefficient of zero point: typical ≤ 0.5 % of Span/10 K
Long-term Drift (per IEC 61298-2)
Ingress Protection (per IEC 60529)
- The Stated ingress Protection only applies when plugged in using mating Connectors that have the appropriate ingress Protection.
- Cable outlet: IP69K
- Metri-Pack Series 150: IP67
- Circular Connector M12 x 1: IP67
- The ingress Protection depends on the Type of Electrical Connection
Temperatures
- Ambient: -25° to +85° C -13° to +185° F
- Medium: -40° to +100° C -40° to +212° F
- Storage: -25° to +85° C -13° to +185° F
Stability
- The Pressure transmitter is resistant to the industrial Standard refrigerants