Hydrostatic level sensor Deltapilot FMB51

Brand: Endress+Hauser

Hydrostatic level sensor Deltapilot FMB51

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Lean Lean

Specs at a Glance

Process pressure / max. overpressure limit:
40 bar (600 psi)
Max. measurement distance:
100m (328ft) H2O
Process temperature:
-10°C...85°C
(14°F…212°F)
Pressure measuring range:
100 mbar...10 bar
(1.5 psi...150 psi)
Main wetted parts:
Alloy C
316L
optional coating AuPt
Material process membrane:
316L, AlloyC
Gold-Rhodium
Accuracy:
Standard 0.2%
Optional 0.1%
Measuring cell:
100 mbar...10 bar
(1.5 psi...150 psi)

Field of application

The Deltapilot FMB51 is a rod version with a fixed process connection. This device with the Contite measuring cell and is typically used in the environmental industry. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)
  • Other industries
  • Life Science

Product Family

  • Deltapilot

Continuous / Liquids

Characteristic / Application

  • Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
  • Hermetically sealed, condensate-resistant and climatic-proofed
  • Rod version

Specialities

  • Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
  • diagnostic functions
  • Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)

Supply / Communication

  • 4...20mA HART:
  • 10,5...45V DC
  • Ex ia: 10,5...30V DC
  • PROFIBUS PA /
  • FOUNDATION Fieldbus:
  • 9...32V DC (Non Ex)

Accuracy

  • Standard 0.2%
  • Optional 0.1%

Long term stability

  • 0.05 % of URL/ year

Ambient temperature

  • -40°C...85°C
  • (-40°F...185°F)

Process temperature

  • -10°C...85°C
  • (14°F…212°F)

Process pressure / max. overpressure limit

  • 40 bar (600 psi)

Pressure measuring range

  • 100 mbar...10 bar
  • (1.5 psi...150 psi)

Main wetted parts

  • Alloy C
  • 316L
  • optional coating AuPt

Process connection

  • Thread:
  • G1 1/2, MNPT1 1/2
  • Flange:
  • DN40...DN100,
  • ASME 2"...4",
  • JIS 10K

Max. measurement distance

  • 100m (328ft) H2O

Communication

  • 4...20 mA HART
  • PROFIBUS PA
  • FOUNDATION Fieldbus

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

Safety approvals

  • Overfill protection WHG
  • SIL

Design approvals

  • EN 10204-3.1
  • NACE MR0175

Drinking water approvals

  • KTW/ NSF

Options

  • Separate housing
  • Initial device settings
  • Overvoltage protection

Application limits

  • If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
  • Observe ratio head pressure : hydrostatic pressure

Pressure

Characteristic

  • Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
  • Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
  • Rod version

Supply voltage

  • 4...20 mA HART
  • 10,5...45 VDC (Non Ex):
  • Ex ia: 10,5...30 VDC
  • PROFIBUS PA:
  • 9...32 VDC (Non Ex)
  • FOUNDATION Fieldbus:

Reference Accuracy

  • Standard 0.2 %
  • Optional 0.1 %

Long term stability

  • 0.05 % of URL/year

Process temperature

  • -10°C...85°C
  • (14°F…212°F)

Ambient temperature

  • -40°C...85°C
  • (-40°F...185°F)

Measuring cell

  • 100 mbar...10 bar
  • (1.5 psi...150 psi)

Smallest calibratable span

  • 10 mbar (1.45 psi)

Vacuum resistance

  • 0 mbar abs.

Max. Turn down

  • 100:1

Max. overpressure limit

  • 40 bar (600 psi)

Process connection

  • Thread:
  • G1 1/2, MNPT1 1/2
  • Flange:
  • DN40...DN100,
  • ASME 2"...4",
  • JIS 10K

Material process membrane

  • 316L, AlloyC
  • Gold-Rhodium

Material gasket

  • Viton, EPDM, Kalrez, none

Fill fluid

  • Inert oil,
  • Synthetic oil

Material housing

  • 316L, Die-cast aluminum

Communication

  • 4...20 mA HART
  • PROFIBUS PA
  • FOUNDATION Fieldbus

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex

Safety approvals

  • Overfill protection WHG
  • SIL

Design approvals

  • EN10204-3.1
  • NACE MR0175

Drinking water approvals

  • KTW/ NSF

Specialities

  • Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
  • Diagnostic functions
show more