Liquiphant FTL62/63/64 FTL63
Brand: Endress+HauserLiquiphant FTL62/63/64 FTL63
Brand: Endress+HauserSpecs at a Glance
(Vacuum...928 psi)
(-58 °F...+302 °F)
(0.4 g/cm³ optional)
Field of application
Specifically developed for the food and beverage and life sciences industries, the Liquiphant FTL63 is compliant to all their hygienic requirements. The proven vibronic technology works reliably in all pumpable liquids, even where other measuring principles reach their limits due to changes in conductivity or dielectric constant (DC value), deposits, foam, turbulences or air bubbles. Therefore, the technology is the perfect substitute for float switches, capacitive or optical sensors.
Liquiphant FTL63 is used for point level detection in process and storage tanks as well as in pipelines.
Process temperature from -50 to +150 °C (-58 to +302 °F)
Viscosities up to 10,000 mm2/s (cSt)
Sensor length up to 3 m (10 ft)
Surface finish: mechanical or electropolished
International hygienic certificates (3-A, EHEDG, ASME BPE), contact material conformity with EC1935/2004, FDA, GB4806
International explosion protection certificates, overfill protection WHG, SIL
CIP/SIP
Features
- Universal use in all pumpable liquids without media adjustment - proven vibronic measurement technology
- High process and product safety through certified hygienic design (3-A, EHEDG, ASME BPE) as well as proven material conformity and traceability through declarations and certificates (e.g. EC1935/2004, FDA and cGMP)
- Easy commissioning with plug & play functionality and minimized maintenance effort thanks to function test via test button or magnetic pin
- Continuous diagnostics as well as traceable and documented on-demand verification without process interruption thanks to Heartbeat Technology
- Intuitive operation via Bluetooth® Technology as well as optical process status indication via colored and bright LED
Specifications
Brand
Industry
- Food & Beverage
- Life Science
Product Family
- Liquiphant
Density
Product Headline
- Hygienic device for density measurement in liquids.
- Point level detection in process and storage tanks as well as in pipelines in hygienic and aseptic applications.
Characteristic / Application
- Premium device for density measurement in hygienic/aseptic applications.
- Focus Food & Beverage and Life Sciences.
- Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
- Modular housing concept.
- Wide range of certificates
Supply / Communication
- via density controller FML621
Ambient temperature
- -40 °C...+70 °C
- (-40...+158 °F)
Process temperature
- 0...+80 °C (+32…+176 °F)
Process pressure
- 0...25 bar (0…362 psi)
Wetted parts
- 316L
Hygienic
- 3-A,
- EHEDG,
- CoC-ASME BPE
Sensor length
- Compact sensor
- Short tube (Liquiphant II)
- 148mm…3000mm (6,00…118")
Output
- Pulse
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, JPN Ex, KC Ex,
- INMETRO Ex, NEPSI Ex/CCC, UK Ex
Specialities
- Density/Concentration measurement in
- combination with density controller FML621,
- Surface finish: mechanical polished (up to 0.3 µm)
Components
- Density Computer FML621
Point Level / Liquids
Characteristic / Application
- Premium device for point level detection
- in hygienic/aseptic applications.
- Focus Food & Beverage and Life Sciences.
- Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
- Modular housing concept.
- Wide range of certificates.
Specialities
- Plug and play functionalities,
- Heartbeat Technology,
- LED Module,
- Bluetooth® Operation and maintenance,
- Surface finish: mechanical or electro-polished,
- Density/Concentration measurement,
- SIL 2/3 according to IEC 61508.
Supply / Communication
- 19 ..253V AC,
- 10...55V DC-PNP,
- 9...20V DC with relay DPDT,
- 19...253V AC or 19...55V DC with relay DPDT,
- 8/16mA HART,
- NAMUR,
- PFM
Ambient temperature
- -50 °C...+70 °C
- (-58 °F...+158 °F)
Process temperature
- -50 °C...+150 °C
- (-58 °F...+302 °F)
Process pressure / max. overpressure limit
- Vacuum...64 bar
- (Vacuum...928 psi)
Min. density of medium
- 0.5 g/cm³
- (0.4 g/cm³ optional)
Main wetted parts
- 316L
Process connection
- Threads (for weld-in adapter):
- G3/4A, G1A
Process connection hygienic
- Tri-Clamp,
- DIN 11851, DIN11864-1
- Ingold,
- Flush mount,
- DRD,
- SMS1145,
- Varivent (Varinline)
Sensor length
- Compact sensor
- Short tube (Liquiphant II)
- 148mm…3000mm (6,00…118")
Communication
- HART
- Bluetooth® wireless technology
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, JPN Ex, KC Ex,
- INMETRO Ex, NEPSI Ex/CCC, UK Ex
Safety approvals
- Overfill protection WHG;
- SIL 2/ SIL 3
Design approvals
- Inspection certificate 3.1, EN10204,
- CoC ASME BPE,
- Conformity to cGMP,
- EU Food Contact Material (EC) 1935/2004,
- US Food Contact Material FDA CFR 21,
- CN Food Contact Material GB 4806,
- Declaration of Conformity ASME B31.3,
- AD2000,
- CRN approval
Hygienic approvals
- 3-A,
- EHEDG,
- CoC-ASME BPE
Options
- LED module,
- Bluetooth module,
- Graphic touch display,
- Customized settings,
- Weld-in adapter
Components
- FTL325P Interface PFM
- FTL325N Interface NAMUR
- FML621 Density controller