Memosens CPS42E

Brand: Endress+Hauser

Memosens CPS42E

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Specs at a Glance

Process temperature:
–15 to 135 °C (5 to 275 °F)
Process pressure:
0.8 to 11 bar (11.6 to 159.5 psi) (absolute)
Measuring range:
–1 500 to 1 500 mV

Field of application

Memosens CPS42E is the high performer for harsh chemical applications, media with low conductivity or considerable organic content. The sensor is designed for fast response especially in applications with fast-changing media. Thanks to Memosens 2.0 digital technology, CPS42E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Media with low conductivities or a high proportion of organic solvents or alcohols and fast changing media:

  • Chemical industry
  • Organic chemicals
  • Power plants, e.g. boiler feed water
  • Laboratory measurements
  • With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Features

  • Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
  • Resistant to poisoning due to permanent refilling of KCl bridge electrolyte and separate reference lead
  • Perfectly suited for quickly changing media: Combination of liquid KCl electrolyte and ceramic junction enables fast response time
  • Applicable at very low conductivities (> 5 µS/cm) thanks to liquid KCl electrolyte
  • Suitable for cleaning in place (CIP) and sterilization in place (SIP)
  • Maximum process safety through non-contact inductive signal transmission
  • Reduced operating costs due to minimized process downtime and extended sensor lifetime

Specifications

Industry

  • Chemical
  • Power & Energy
  • Life Science

Product Family

  • Memosens

ORP / Redox

Application

  • Media with very low conductivity or a high proportion of organic solvents or alcohol:
  • • Chemical industry
  • • Organic chemicals
  • • Power stations
  • • Laboratory measurements

Characteristic

  • Digital ORP electrode for process engineering with ceramic junction
  • and KCl liquid electrolyte

Measuring range

  • –1 500 to 1 500 mV

Measuring principle

  • Liquid-KCl filling and ceramic junction

Design

  • All shaft lengths with temperature sensor

Material

  • Sensor shaft: Glass to suit process
  • ORP measuring element: Platinum
  • Metal lead: Ag/AgCl
  • Open aperture: Ceramic junction, zirconium dioxide
  • O-ring: FKM
  • Process coupling: PPS fiber-glass reinforced
  • Nameplate: Ceramic metal oxide

Dimension

  • Diameter: 12 mm (0.47 inch)
  • Shaft length: 120, 225, 360 and 425 mm
  • (4.72, 8.86, 14.17 and 16.73 inch)

Process temperature

  • –15 to 135 °C (5 to 275 °F)

Process pressure

  • 0.8 to 11 bar (11.6 to 159.5 psi) (absolute)

Temperature sensor

  • NTC 30k

Ex certification

  • With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
  • hazardous areas Zone 0, Zone 1 and Zone 2.

Connection

  • Inductive, contactless connection head with Memosens 2.0 technology

Ingress protection

  • IP68

Additional certifications

  • Additional certifications

  • Chemical Industry
  • Organic Chemicals
  • Power Plants, e.g. Boiler Feed Water
  • Laboratory Measurements
show more