Temperature Engineered Solution TMS01

Brand: Endress+Hauser

Temperature Engineered Solution TMS01

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Xpert Xpert

Specs at a Glance

Max. immersion length on request:
up to 30.000,00 mm (1181'')
Response time:
depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
Accuracy:
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
Max. process pressure (static):
at 20 °C: 100 bar (1450 psi)
Operating temperature range:
Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 920 °C
(max. 1.688 °F)
Type N:
max. 1.150 °C
(max. 2.102 °F)
Type T:
max. 370 °C
(max. 698 °F)

Field of application

By complying with the highest safety standards, iTHERM TMS01 can be customized for various applications. Bendable into a 3D layout, it provides a complete temperature profile just by using one nozzle. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available either with TC or RTD technology or with our iTHERM StrongSens.

Petrochemical industry

Oil & Gas industry

Heavy Chemical processes

Features

  • Easy-to-use device with modular and flexible design, ready to be installed either for direct contact measurements or by means of sensor-dedicated protecting tubes. The device can also be installed in thermowells already in place
  • Infinite layouts of 3D sensors distribution for any desired process monitoring configuration
  • High degree of customization thanks to a modular product design for easy installation, process integration and maintenance
  • High degree of insert process compatibility as per standard IEC 60584, ASTM E230 and IEC 60751
  • On-board electronic heat protection for highest product durability
  • Compliance to different types of protection for use in hazardous locations for easy process integration

Specifications

Industry

  • Chemical
  • Power & Energy
  • Oil & Gas
  • Other industries

Product Family

  • iTHERM MultiSens

Thermometer

Characteristic / Application

  • metric style
  • easy-to-use
  • suitable for hazardous areas
  • flanged process connection
  • light chemical processes
  • 3D sensors distributions
  • modular design
  • replaceable sensors during shutdown

Thermowell / protection tube

  • without (for direct contact sensors type)
  • with (for replaceable sensors)
  • with (for increased mechanical protection)
  • Multi-thermowells, each one dedicated to a sensor

Insert / probe

  • mineral insulated (MI), flexible
  • mineral insulated (MI), flexible, with its own thermowell

Outer diameter protection tube / Insert

  • 6,0 mm (0,24'')
  • 8,0 mm (0,31")
  • 10,29 mm (1/8")

Max. immersion length on request

  • up to 30.000,00 mm (1181'')

Material protection tube/ thermowell

  • 1.4401 (316)
  • 1.4435 (316L)
  • 1.4541 (321)
  • 1.4550 (347)
  • Alloy 600 (2.4816)

Process connection

  • flange:
  • 2" ASME/ANSI B16.5 150
  • ...600
  • 3" ASME/ANSI B16.5 150
  • ..600
  • 4" ASME/ANSI B16.5 150
  • 6" ASME/ANSI B16.5 150
  • 8" ASME/ANSI B16.5 150
  • DN80 EN/DIN 1092.1 PN10
  • ...PN100
  • DN100 EN/DIN 1092.1 PN10
  • DN125 EN/DIN 1092.1 PN10
  • DN150 EN/DIN 1092.1 PN10
  • DN200 EN/DIN 1092.1 PN10

Tip shape

  • straight

Operating temperature range

  • Type K:
  • max. 1.150 °C
  • (max. 2.102 °F)
  • Type J:
  • max. 920 °C
  • (max. 1.688 °F)
  • Type N:
  • Type T:
  • max. 370 °C
  • (max. 698 °F)

Max. process pressure (static)

  • at 20 °C: 100 bar (1450 psi)

Accuracy

  • class 2 acc. to IEC 60584
  • ASTM E230 and ANSI MC 96.1

Response time

  • depending on configuration:
  • TC:
  • t50 = 2 s
  • t90 = 5 s
  • RTD:
  • t50 = 0,8s
  • t90 = 2s

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

  • ATEX
  • UL
  • FM
  • CSA
  • NEPSI

Certification

  • SIL (transmitter only)
show more