E+PLC100 is a combination single box PLC designed to meet the stringent regulatory requirements of thermal and other advanced manufacturing industries. 

By utilizing the open industry standard IEC 61131-3 Codesys platform, E+PLC enables simplified engineering through a single integrated programming and visualization environment.

Eurotherm’s unique PID control functions are built-in, enabling faster commissioning and tighter control of the overall process, as well as easing conformance to regulatory and end-customer requirements.

Data management embedded in E+PLC helps manufacturers meet strict regulatory process data requirements.

Ethernet communications offer connectivity to IIoT (Industrial Internet of Things) and Industry 4.0 technologies, such as EOS (Eurotherm Online Services). 

To assist with operational efficiency, E+PLC100 includes a fully configurable touchscreen HMI, as well as an embedded webserver for remote viewing on mobile devices.
Features
  • Easy to use function block libraries
  • IEC 61131-3 Programming Languages

Specifications

Brand

Accuracy

  • Input [Calibration Accuracy (Instrument at 25° C)]: 1.5 mV + 0.063 % of Reading
  • Input [Calibration Accuracy (Instrument at 25° C)]: 4.6 μV + 0.053 % of Reading
  • Input [Calibration Accuracy (Instrument at 25° C)]: 420 μV + 0.044 % of Reading
  • Input [Calibration Accuracy (Instrument at 25° C)]: 7.5 μV + 0.052 % of Reading
  • mA Input Shunt Accuracy: 0.1 % of Input for Shipped 2.49 ohms Shunt
  • Pt100 (Calibration Accuracy): ± 0.31° C (± 0.558° F) ± 0.023 % of Measurement in °C at 25° C (77° F) Ambient
  • Voltage Output (< ± 50 mV), Current Output (< ± 100 μA) Calibration Accuracy: ± 1 % of Reading

Approvals & Certifications

  • CCC
  • CE
  • EAC
  • EMC Emission: Standard Units to BS EN 61326 Class B (Light Industrial), Immunity: BS EN 61326 Industrial
  • IEC 61131-3, 751, 584.1
  • LVD BS EN 61326 Class A (Heavy Industrial)
  • REACH
  • RoHS
  • UL (C,US)
  • WEEE

Approvals & Certifications

  • Input (Dielectric Strength): BS EN 61010

Battery Life

  • Real Time Clock Battery (Replacement Period): 3-Years Typical
  • Real Time Clock Battery (RTC Aging): 1 to 10-Years < ± 5 ppm

Communication

  • FTP
  • Network Communication (Protocols): Modbus TCP/IP Master/Slave
  • Network Communication: 10/100Base-T Ethernet IEEE 802.3
  • SNTP
  • USB 1.1

Control Functions Characteristics

  • PID Control (Autotune, Cutback etc.)

Current

  • Active (Current On) Contact Closure Logic Input [Input Current (Input at 12 V)]: 0-44 mA
  • Active (Current On) Current Sourcing, Active (Current On) Contact Closure Logic Input [Short Circuit Output Current, Input Current at 0 V]: 6-44 mA (Steady State to Switch Current)
  • Contact Closure Input [Closed Circuit Sensing Current (Source)]: 5.5-6.5 mA
  • Form A N/O Relay (Current through Terminals): 2 A
  • Form A N/O Relay Output (Current through Terminals): 1 A
  • Inactive (Current Off) Current Sourcing (Output Source Leakage Current Into Short Circuit): 0-100 μA
  • Pt100, Max.
  • USB Port: < 100 mA - Max.

Display

  • 3.5” TFT Color Screen Display (320 Pixels Wide x 240 Pixels High) with PCT (Projected Capacitive Touchscreen)
  • Network Communication: Amber LED Flashing Shows Link Activity
  • Network Communication: Green LED Illuminated Shows Link Connected

Electrical Connectors

  • 24 to 16 AWG (0.205 to 1.31 mm²)
  • Network Communication (Termination): RJ45

Environmental Protection

  • IP10
  • IP52
  • IP66
  • NEMA 12

Humidity

  • Operating, Storage Humidity: 5 to 85 % Relative Humidity, Non-Condensing

Input

  • 0-20 mA
  • -80 mV to 10 V
  • Active (Current On) Contact Closure Logic Input (Open Circuit Input Voltage): 11-13 V
  • Analog Input (Common Mode Voltage): 250 Vac, Max.
  • Analog Input (Series Mode Voltage): 280 mV at Lowest Range
  • Analog Input (Series Mode Voltage): 5 V Peak-to-Peak at Highest Range
  • Dielectric Strength: 1,500 Vac Channel to Ground
  • Dielectric Strength: 2,500 Vac Channel to Channel
  • Overvoltage Protection: ± 200 V Peek to Peek between Terminals (Transient< 1 milliseconds)
  • Overvoltage Protection: ± 30 Vrms

Input Impedance

  • 10 V: 62.5 kiloohms for Input > 5.6 V
  • 10 V: 667 kiloohms for Input 100 megaohms

Isolation

  • Current, Voltage Output, Form A N/O Relay Output: 300 Vrms or DC, Double Insulated from Processor Electronics

Length

  • Network Communication: 328 feet (100 metres) - Max.

Linearity

  • Pt100: 0.0033 % (Best Fit Straight Line)

Linearization

  • RTD Typical (Linearization Accuracy): 0.01° to 0.09° C
  • Thermocouple: 0.02° to 1.7° C

Load Resistance

  • Current Output: 500 ohms, Max.
  • Voltage Output: 500 ohms Min.

Mounting

  • Panel Mount: 1/4” DIN

Operating Temperature

  • 0° to 55° C (32° to 131° F)

Output

  • Active (Current On) Current Sourcing (Voltage Output Across Terminal): 11-13 V
  • Configurable within 0-10 Vdc
  • Configurable within 0-20 mA
  • Inactive (Current Off) Current Sourcing (Voltage Output Across Terminal): 0-300 mV

Power

  • Form A N/O Relay [Contact Switching Power (Resistive)]: 100 mA Min. at 12 V
  • Form A N/O Relay [Contact Switching Power (Resistive)]: 2 A, Max.
  • Form A N/O Relay Output [Contact Switching Power (Resistive)]: 1 A, Max.
  • Form A N/O Relay Output [Contact Switching Power (Resistive)]: 5 mA Min. at 5 V
  • Power Dissipation: 9 W, Max.

Power Requirement

  • Real Time Clock Battery: Lithium Poly-Carbonmonofluoride

Resistance

  • Active (Current On) Contact Closure Logic Input [Closed Circuit (Active) Resistance]: 500 ohms
  • Contact Closure Input [Closed Circuit (Active) Resistance]: 600 ohms
  • Input (Min. Break Resistance): 12.5 kiloohms for 2 V & 10 V Ranges
  • Input (Min. Break Resistance): 5 kiloohms for 40 mV & 80 mV Ranges
  • Input Resistance: 20 milliohms
  • mA Input (External Shunt): 1 ohm to 1 Kiloohm
  • Pt100 (Lead Resistance): 0 to 22 ohms
  • Pt100: 0 to 400 ohms

Resolution

  • Current, Voltage Output: > 11-bits
  • Input: 1.9-500 μV
  • Pt100: 0.05° C

RTD Type

  • Cu10
  • Cu53
  • JPt100
  • Ni100
  • Ni120
  • Pt100
  • Pt100A

Sample Rate

  • Data Recording Update/Archiving: 8 Hz

Sensor, Probe Type

  • B Thermocouple
  • C Thermocouple
  • D Thermocouple
  • E Thermocouple
  • G2 Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • Mi/NiMo
  • NiMo/NiCo Thermocouple
  • N Thermocouple
  • PlatineL Thermocouple
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple

Shock

  • BS EN 61131-2

Stability

  • Real Time Clock Battery: 0° to 55° C (32° to 131° F) ≤ ± 3.5 ppm

Storage Temperature

  • -20° to 70° C (-4° to 158° F) - Max.

Supply Voltage

  • 100-230 Vac ± 15 % at 48 to 62 Hz
  • 24 Vac (10 % -15 %) at 48 to 62 Hz
  • 24 Vdc (20 % / 15 %)

Temperature Coefficient

  • -40° to 40 mV, -80° to 80 mV, -2 to 2 V Input: 13 ppm of Input/°C
  • Input Resistance: 25 ppm of Input/°C
  • Pt100: ± 0.01° C/°C ± 25 ppm/°C Measurement in °C from 25° C (77° F) Ambient

Temperature Range

  • RTD Typical: -220° to 850° C (-364° to 1,562° F)
  • Thermocouple Typical: -270° to 2,495° C (-454° to 4,523° F)

Thermal Drift

  • Current, Voltage Output: < 100 ppm/°C

Torque

  • 0.4 Nm (3.54 In/Lbs)

Update Time

  • Current, Voltage Output (Update Rate): 125 milliseconds
  • Update Rate: 8 milliseconds, Max.

Vibration

  • 2 G, 5 to 150 Hz, 0.5 Octave Per Minute