Fluke TiS20+ / TiS20+ MAX Thermal Imaging Camera

Brand: Fluke Corporation

hether you are up on the roof inspecting heating, ventilation and air conditioning, deep in the plant scanning a motor, or if you are locking out an electrical panel, you rely on your tools to have the power and features to get your job done fast.

The Fluke TiS20+ and TiS20+ MAX handheld thermal cameras puts the power of thermal imaging at your fingertips. Designed to make your job quicker and easier.

Let Fluke IR-Fusion™ make your job easier by using a thermal image overlaid on a visual light image to give you the full picture of where the issue is before it becomes a problem. 

Simply slide your finger across the screen to adjust the level of infrared. Whether you are finding an uneven load on a switchgear or inspecting a ventilation system, the Fluke TiS20+ helps you detect issues quickly.

The TiS20+ and TiS20+ MAX can work without a break, with a battery life of over 5 hours of continuous use making it the longest battery life in a Fluke thermal camera ever. 

Save your battery life in-between inspection points with sleep mode. Simply press the power button one time and you are back up and running.
Features
  • Continuous touchscreen IR-Fusion™
  • 5 hours battery life
  • Can withstand drop up to 2 meter
  • Water and dust resistant—IP54 enclosure rating
  • Automatically organize and file thermal images with Fluke Connect™ Asset Tagging
  • 120 x 90 infrared resolution

Specifications

Infrared Resolution

  • 120 x 90 - 10,800 pixels

IFOV

  • 7.6 mRad, D: S 130: 1

Field of View

  • 50° H x 38° V

Focus System

  • Fixed Focus

Data Transfer

  • Mini USB used to transfer image to PC

Wireless Connectivity

  • 802.11 b/g/n (2.4 GHz)

Thermal Sensitivity

  • 60 mK

Temperature Measurement Range

  • TiS20+: -20° C to 150° C (-4° F to 302° F)
  • iS20+ Max. -20° C to 400° C (-4° F to 752° F)

Accuracy

  • Target temp at or over 0° C: Accuracy: ± 2° C or ± 2 % at 25° C, whichever is greater.

Infrared Spectral Band

  • 8 μm to 14 μm

Operating Temperature

  • -10° C to 50° C
  • 14° F to 122° F

Relative Humidity

  • 95 % Non-Condensing

Safety

  • IEC 61010-1: Pollution Degree 2

Electromagnetic Compatibility

  • EN 61326-1, CISPR 11: Group 1, Class A

Vibration and Shock

  • 0 Hz to 150 Hz, 0.15 mm
  • IEC 60068-2-6, 30 g, 11 ms
  • IEC 60068-2-27

Enclosure Rating

  • IP54
show more