Extended Specs at a Glance
Output / communication:
1/2 x 4 to 20 mA, HART, Profibus, FF
Additional second output possible, also later
Additional second output possible, also later
Input:
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Ingress protection:
IP66/67, NEMA 4X
Field of application
The Liquiline M CM42 is a versatile transmitter that ensures safe measurement across all process applications, including hazardous areas. It seamlessly integrates into your process control system, offering simplicity and speed in operation and maintenance. This product is designed to provide reliable and efficient process control.
Specifications
Brand
Industry
- Chemical
- Food & Beverage
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Life Science
Product Family
- Liquiline
Conductivity
Application
- Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
- Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
- Resistance measurement
Design
- Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
- Plastic or stainless steel housing with EPDM sealings
Dimension
- Plastic housing:
- 144 x 144 x 148 mm
- 5.67 x 5.67 x 5.83 inch
- Stainless Steel:
- 174 x 174 x 134 mm
- 6.85 x 6.85 x 5.28 inch
Temperature sensor
- Applicable:
- Pt100, Pt1000
Ex certification
- ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
- IP66/67, NEMA 4X
Input
- One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
- 1/2 x 4 to 20 mA, HART, Profibus PA, FF
- Additional second output possible, also later
ORP / Redox
Application
- Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
- Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
- ORP measurement
Design
- Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
- Plastic or stainless steel housing with EPDM sealings
Dimension
- Plastic housing:
- 144 x 144 x 148 mm
- 5.67 x 5.67 x 5.83 inch
- Stainless Steel:
- 174 x 174 x 134 mm
- 6.85 x 6.85 x 5.28 inch
Temperature sensor
- Applicable:
- Pt100, Pt1000, NTC 30K
Ex certification
- ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
- IP66/67, NEMA 4X
Input
- One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
- 1/2 x 4 to 20 mA, HART, Profibus, FF
- Additional second output possible, also later
Oxygen
Application
- Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
- Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
- Connection of oxygen sensors with Memosens coupling
Design
- Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
- Plastic or stainless steel housing with EPDM sealings
Dimension
- Plastic housing:
- 144 x 144 x 148 mm
- 5.67 x 5.67 x 5.83 inch
- Stainless Steel:
- 174 x 174 x 134 mm
- 6.85 x 6.85 x 5.28 inch
Ex certification
- ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
- IP66/67, NEMA4X
Input
- One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
- 1/2 x 4 to 20 mA, HART, Profibus PA, FF
- Additional second output possible, also later
pH
Application
- Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
Characteristic
- Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
Measuring principle
- Potentiometric pH measurement
Design
- Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
Material
- Plastic or stainless steel housing with EPDM sealings
Dimension
- Plastic housing:
- 144 x 144 x 148 mm
- 5.67 x 5.67 x 5.83 inch
- Stainless Steel:
- 174 x 174 x 134 mm
- 6.85 x 6.85 x 5.28 inch
Temperature sensor
- Applicable:
- Pt100, Pt1000, NTC 30K
Ex certification
- : ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
Ingress protection
- IP66/67, NEMA 4X
Input
- One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication
- 1/2 x 4 to 20 mA, HART, Profibus PA, FF
- Additional second output possible, also later
- Chemicals
- Food & Beverages
- Life Sciences
- Power & Energy
- Oil & Gas
- Primaries & Metal