Transmitter Liquiline, 2-wire CM42

Brand: Endress+Hauser

Transmitter Liquiline, 2-wire CM42

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Output / communication:
1/2 x 4 to 20 mA, HART, Profibus, FF
Additional second output possible, also later
Input:
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
Ingress protection:
IP66/67, NEMA 4X

Field of application

The Liquiline M CM42 is a versatile transmitter that ensures safe measurement across all process applications, including hazardous areas. It seamlessly integrates into your process control system, offering simplicity and speed in operation and maintenance. This product is designed to provide reliable and efficient process control.

Specifications

Industry

  • Chemical
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Life Science

Product Family

  • Liquiline

Conductivity

Application

  • Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

  • Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

  • Resistance measurement

Design

  • Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol

Material

  • Plastic or stainless steel housing with EPDM sealings

Dimension

  • Plastic housing:
  • 144 x 144 x 148 mm
  • 5.67 x 5.67 x 5.83 inch
  • Stainless Steel:
  • 174 x 174 x 134 mm
  • 6.85 x 6.85 x 5.28 inch

Temperature sensor

  • Applicable:
  • Pt100, Pt1000

Ex certification

  • ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingress protection

  • IP66/67, NEMA 4X

Input

  • One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

  • 1/2 x 4 to 20 mA, HART, Profibus PA, FF
  • Additional second output possible, also later

ORP / Redox

Application

  • Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

  • Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

  • ORP measurement

Design

  • Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol

Material

  • Plastic or stainless steel housing with EPDM sealings

Dimension

  • Plastic housing:
  • 144 x 144 x 148 mm
  • 5.67 x 5.67 x 5.83 inch
  • Stainless Steel:
  • 174 x 174 x 134 mm
  • 6.85 x 6.85 x 5.28 inch

Temperature sensor

  • Applicable:
  • Pt100, Pt1000, NTC 30K

Ex certification

  • ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingress protection

  • IP66/67, NEMA 4X

Input

  • One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

  • 1/2 x 4 to 20 mA, HART, Profibus, FF
  • Additional second output possible, also later

Oxygen

Application

  • Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

  • Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

  • Connection of oxygen sensors with Memosens coupling

Design

  • Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol

Material

  • Plastic or stainless steel housing with EPDM sealings

Dimension

  • Plastic housing:
  • 144 x 144 x 148 mm
  • 5.67 x 5.67 x 5.83 inch
  • Stainless Steel:
  • 174 x 174 x 134 mm
  • 6.85 x 6.85 x 5.28 inch

Ex certification

  • ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingress protection

  • IP66/67, NEMA4X

Input

  • One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

  • 1/2 x 4 to 20 mA, HART, Profibus PA, FF
  • Additional second output possible, also later

pH

Application

  • Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas

Characteristic

  • Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering

Measuring principle

  • Potentiometric pH measurement

Design

  • Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol

Material

  • Plastic or stainless steel housing with EPDM sealings

Dimension

  • Plastic housing:
  • 144 x 144 x 148 mm
  • 5.67 x 5.67 x 5.83 inch
  • Stainless Steel:
  • 174 x 174 x 134 mm
  • 6.85 x 6.85 x 5.28 inch

Temperature sensor

  • Applicable:
  • Pt100, Pt1000, NTC 30K

Ex certification

  • : ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex

Ingress protection

  • IP66/67, NEMA 4X

Input

  • One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

  • 1/2 x 4 to 20 mA, HART, Profibus PA, FF
  • Additional second output possible, also later

  • Chemicals
  • Food & Beverages
  • Life Sciences
  • Power & Energy
  • Oil & Gas
  • Primaries & Metal
show more