High temperature TAF11

Brand: Endress+Hauser

High temperature TAF11

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Max. process pressure (static):
at 20 °C: 1 bar (15 psi)
Max. immersion length on request:
up to 4.000,00 mm (157,48'')
Accuracy:
class 2 acc. to IEC 60584
Operating temperature range:
Type K:
-40 °C ...1.300 °C
(-40 °F ...2.372 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F)
Type N:
-40 °C ...1.150 °C
(-40 °F ...2102 °F)
Type S:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type R:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type B:
600 °C ...1.600 °C
(1.112 °F ...2.912 °F)

Field of application

Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials serves as protection from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

Applicable for steel treatment (annealing), concrete furnaces and primaries. It contains a single or double TC insert and a ceramic protection tube.

Process temperatures: up to +1600 °C (+2912 °F)

Features

  • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
  • Long term stable measurement due to sensor protection with non-porous materials
  • Flexible product selection by modular design
  • Optimized life cycle costs by means of replaceable spare parts

Specifications

Industry

  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Other industries

Product Family

  • iTHERM FlameLine

Thermometer

Characteristic / Application

  • metric style
  • modular temperature assembly
  • high temperature probe (furnace)
  • incl. single ceramic thermowell

Thermowell / protection tube

  • ceramic protection tube

Insert / probe

  • ceramic capilarry, rigid

Outer diameter protection tube / Insert

  • 14,0 mm (0,55")
  • 16,0 mm (0,59")
  • 17,0 mm (0,68")
  • 22,0 mm (0,87")
  • 24,0 mm (0,94")
  • 26,6 mm (1,05")

Max. immersion length on request

  • up to 4.000,00 mm (157,48'')

Material protection tube/ thermowell

  • Ceramic (C610)
  • silicon nitride ceramic (SiN)
  • sintered silicon carbide (SiC)

Process connection

  • compression fitting:
  • G3/4"
  • G1"
  • G11/2"
  • adjustable Flange

Tip shape

  • straight

Operating temperature range

  • Type K:
  • -40 °C ...1.300 °C
  • (-40 °F ...2.372 °F)
  • Type J:
  • -40 °C ...750 °C
  • (-40 °F ...1.382 °F)
  • Type N:
  • -40 °C ...1.150 °C
  • (-40 °F ...2102 °F)
  • Type S:
  • 0 °C ...1.600 °C
  • (32 °F ...2.912 °F)
  • Type R:
  • Type B:
  • 600 °C ...1.600 °C
  • (1.112 °F ...2.912 °F)

Max. process pressure (static)

  • at 20 °C: 1 bar (15 psi)

Accuracy

  • class 2 acc. to IEC 60584

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Certification

  • SIL (transmitter only)
show more