Sensor CCS51

Brand: Endress+Hauser

Sensor CCS51

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Specs at a Glance

Process pressure:
1 bar (14.5 psi)
Process temperature:
+0 to 55 °C (32 to 130°F), non-freezing
Measuring range:
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
Measuring method:
- Closed, membrane covered measuring cell
- Reduction of free chlorine at the cathode

Field of application

CCS51 is a robust, low-maintenance sensor for free chlorine. It provides high-precision measurement with long-term stability in drinking water, pool and process water and ensures consistent disinfection monitoring even at low water volumes. The analog free chlorine sensor features extremely fast response times guaranteeing efficient process control and safe processes. CCS51 ensures continuity for the installed base of analog free chlorine measuring points.

CCS51 is an analog free chlorine sensor for skid builders and end customers. It measures reliably in:

  • Drinking water - to ensure reliable disinfection
  • Process water - for hygienic and safe packaging and bottling of products
  • Utilities - to detect the absence or presence of free chlorine
  • Pool water - to dose disinfectant efficiently

Features

  • Fast response time (t90 < 25 s) provides accurate process view and enables prompt reaction to process changes as well as efficient process control.
  • Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for individually adapted disinfectant dosing.
  • The low-maintenance, amperometric sensor reduces the cost of ownership of the measuring point, particularly compared to colorimetric measuring systems.
  • Connection to the Liquisys chlorine transmitter ensures continuity for the installed base of analog free chlorine measuring points.

Specifications

Industry

  • Water, Wastewater & Waste
  • Food & Beverage

Product Family

  • Memosens

Disinfection

Application

  • Drinking water - to ensure reliable disinfection
  • Process water - wide range of application due to large measuring range
  • Food - to secure absence/presence of free chlorine
  • Pool water -efficient dosing thanks to precise measurement

Characteristic

  • Amperometric measurement of dissolved free chlorine

Measuring range

  • Trace: 0 to 5 mg/l HOCl
  • Standard: 0 to 20 mg/l HOCl

Measuring method

  • - Closed, membrane covered measuring cell
  • - Reduction of free chlorine at the cathode

Design

  • Closed amperometric 2-electrode measuring cell with PVDF membrane

Material

  • Sensor shaft: POM
  • Membrane: PVDF
  • Membrane cap: PVDF

Dimension

  • Diameter: 25 mm (0.98 in)
  • Length: 161 mm (6.34 in)

Process temperature

  • +0 to 55 °C (32 to 130°F), non-freezing

Process pressure

  • 1 bar (14.5 psi)

Temperature sensor

  • 10k NTC

Connection

  • analog with fixed cable
show more