Ambient Temperature Range
- -20° to 80° C (-4° to 176° F)
Applications
- Hydraulic & Pneumatic Applications
- Leak Detection
- Pumps & Compressors
- Tank Monitoring
- Water Management
Approvals & Certifications
Diaphragm Material
- NBR Diaphragm < 225 psig (Measuring Element)
Electrical Connectors
- 18" Integral Cable
- 6.3 mm Spade Terminals
Electrical Rating
- Up to 28 Vdc 2 A
- Up to 50 Vac 4 A
Environmental Protection
- IP00: Spade Terminals
- IP67: Cable Connection
Hysteresis
- Diaphragm Typical: ≤ 10 % of Full Scale Adjustment Range, Min. 100 psig (689.5 kPa, 6.895 bar)
- Piston Typical: Max.
Media
- Diaphragm Typical: Compressed Air or Corrosive Liquids
- Piston Typical: Self Lubricating Fluids Such as Hydraulic Oil or Grease
Process Connection Material
Process Temperature
- -20° to 80° C (-4° to 176° F)
Proof Pressure
- bar: 59.98 to 344.7
- kPa: 5,998 to 34,470
- psig: 870 to 5,000
Set Point - Decreasing
- bar: 0.2 to 317.1
- kPa: 20.7 to 31,716
- psig: 3 to 4,600
Set Point - Increasing
- bar: 0.2 to 317.1
- kPa: 20.7 to 31,716
- psig: 3 to 4,600
Storage Temperature
- -20° to 80° C (-4° to 176° F)
Switch Type
- SPDT, Micro Switch Silver-Plated Contacts, Gold-Plated Contacts Available on Request
System Pressure
- bar: 59.98 to 344.7
- kPa: 5,998 to 34,474
- psig: 870 to 5,000