8045 Electromagnetic Flow Transmitter
Brand: Burkert Fluid Control SystemsThe Magflowmeter 8045 has been designed for pipes with diameters ranging from 1/4" to 16" and liquids having a conductivity > 20 µS/cm. The transmitter has a large display, a keyboard and provides 4-20 mA, relay and pulse outputs.
The version with a stainless steel sensor has been designed for applications with high pressures 230 psi and high temperatures (up to 230° F).
Features
- Sensor in solid state technology
- Shows both flow rate and volume
- Simulation: All outputs signals provided without the need for real flow
- Clean in process (CIP)
- FDA approved
Specifications
Wetted Material
- Sensor Armature: 316L Stainless Steel, DIN 1.4404, PVDF
- Electrode Holder (Stainless Steel Sensor Version): PEEK
- Clamp: Stainless Steel 1.4404/316L
- Earth Ring & Electrode: Stainless Steel 1.4404/316L, Alloy C2
- Seal: FKM, EPDM, FEP
Non-Wetted Material
- Housing, Cover & Union Nut: Polycarbonate (PC), Back PPA
- Lid: PC, PSU
- Front Panel Film: Polyester
- Screw: Stainless Steel
- Mounting Ring: Polysulphone, glass fibre reinforced
- Seal: NBR, Silicone
- Cable Gland: PA with neoprene seal
- Armature: Stainless Steel 1.4404/316L
Operating Voltage
- 18-36 Vdc ± 0.5 %, Filtered & Regulated (3-Wires)
Approvals & Certifications
- CE
- FDA
- UL
- PED
Measuring Range
- Flow Velocity: 0.2 to 10 m/sec
- Flow Rate: 0.4 to 75,000 l/min
Linearity
- ± 0.5 % of Full Scale
Repeatability
- ± 0.25 % of the Measured Value
Measurement Deviation
- Standard K-factor: ± 3.5 % of the Measured Value
- Teach-In: ± 0.5 % of the Measured Value
Medium Temperature
- PVDF: 0° to 80° C (32° to 176° F)
- Stainless Steel: -15° to 110° C (5° to 230° F)
Fluid Pressure
- Max. PN 10 (145.1 PSI)
- Max. PN 16 (232.16 PSI)
Pipe Diameter
- 1/4" to 16" (DN 06 to DN 400)
Electrical Connection
- Cable Gland M20 x 1.5
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Operating Temperature
- -10° to 60° C (14° to 140° F)
Humidity
- < 80 % RH, Non-Condensing
Environmental Protection
- IP65