Vibronic level switch Liquiphant FTL31/33 FTL33

Brand: Endress+Hauser

Vibronic level switch Liquiphant FTL31/33 FTL33

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Fundamental Fundamental

Specs at a Glance

Process pressure / max. overpressure limit:
Vacuum ... 40 bar
(Vacuum ... 580 psi)
Process temperature:
-40 °C ... 150 °C
(-40 °F ... 302 °F)
Min. density of medium:
>0,7g/cm³
(>0,5g/cm³ optional)

Field of application

The Liquiphant FTL33 is a vibronic point level switch for liquids in hygienic applications. The FTL33 is especially designed for food & beverage applications and used for overfill prevention or pump dry-run protection. The measurement is not affected by conductivity, build-up, turbulence, flow or air bubbles and and does not require calibration. The IO-Link capability allows easy and time-saving configuration.

Features

  • Plug & play sensor with no need for adjustment with changing media
  • Smallest vibronic sensor in the market
  • No calibration required
  • Robust design assures high durability.

Specifications

Industry

  • Food & Beverage
  • Other industries

Target Customer

  • Food & beverage industry

Product Family

  • Liquiphant

Point Level / Liquids

Characteristic / Application

  • Point level switch for liquids
  • in the food sector

Supply / Communication

  • 20 ... 253V AC/DC, 2-wire
  • 10 ... 30V DC-PNP, 3-wire

Ambient temperature

  • -40 °C ... 70 °C
  • (-40 °F ... 158 °F)

Process temperature

  • -40 °C ... 150 °C
  • (-40 °F ... 302 °F)

Process pressure / max. overpressure limit

  • Vacuum ... 40 bar
  • (Vacuum ... 580 psi)

Min. density of medium

  • >0,7g/cm³
  • (>0,5g/cm³ optional)

Main wetted parts

  • 316L

Process connection

  • Threads:
  • G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1

Process connection hygienic

  • Flush mount by use of weld in adapter
  • DIN11851
  • Tri-Clamp

Communication

  • AC/DC, DC-PNP, IO-Link

Certificates / Approvals

  • CSA C/US, EAC

Safety approvals

  • Overfill protection WHG
  • Leakage

Design approvals

  • EN 10204-3.1

Hygienic approvals

  • 3A, EHEDG

Options

  • Switching delay
  • Cleaned from oil+grease,
  • Surface finish measurement
show more