Vibronic level switch Liquiphant FTL31/33 FTL33
Brand: Endress+HauserVibronic level switch Liquiphant FTL31/33 FTL33
Brand: Endress+Hauser
Fundamental Specs at a Glance
Process pressure / max. overpressure limit:
Vacuum ... 40 bar
(Vacuum ... 580 psi)
(Vacuum ... 580 psi)
Process temperature:
-40 °C ... 150 °C
(-40 °F ... 302 °F)
(-40 °F ... 302 °F)
Min. density of medium:
>0,7g/cm³
(>0,5g/cm³ optional)
(>0,5g/cm³ optional)
Field of application
The Liquiphant FTL33 is a vibronic point level switch for liquids in hygienic applications. The FTL33 is especially designed for food & beverage applications and used for overfill prevention or pump dry-run protection. The measurement is not affected by conductivity, build-up, turbulence, flow or air bubbles and and does not require calibration. The IO-Link capability allows easy and time-saving configuration.
Features
- Plug & play sensor with no need for adjustment with changing media
- Smallest vibronic sensor in the market
- No calibration required
- Robust design assures high durability.
Specifications
Brand
Industry
- Food & Beverage
- Other industries
Target Customer
- Food & beverage industry
Product Family
- Liquiphant
Point Level / Liquids
Characteristic / Application
- Point level switch for liquids
- in the food sector
Supply / Communication
- 20 ... 253V AC/DC, 2-wire
- 10 ... 30V DC-PNP, 3-wire
Ambient temperature
- -40 °C ... 70 °C
- (-40 °F ... 158 °F)
Process temperature
- -40 °C ... 150 °C
- (-40 °F ... 302 °F)
Process pressure / max. overpressure limit
- Vacuum ... 40 bar
- (Vacuum ... 580 psi)
Min. density of medium
- >0,7g/cm³
- (>0,5g/cm³ optional)
Main wetted parts
- 316L
Process connection
- Threads:
- G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1
Process connection hygienic
- Flush mount by use of weld in adapter
- DIN11851
- Tri-Clamp
Communication
- AC/DC, DC-PNP, IO-Link
Certificates / Approvals
- CSA C/US, EAC
Safety approvals
- Overfill protection WHG
- Leakage
Design approvals
- EN 10204-3.1
Hygienic approvals
- 3A, EHEDG
Options
- Switching delay
- Cleaned from oil+grease,
- Surface finish measurement