Accuracy
- ± 0.25 % of Span
- ± 0.50 % of Span
Ambient Temperature Range
- -20° to 80° C (-4° to 176° F)
Applications
- Chemical & Petrochemical
- Machine Building
- Oil & Gas Applications
Approvals & Certifications
- ATEX
- CRN
- CSA
- DNV GL
- EAC
- EMC
- Ex
- FM
- GL
- IECEx
- INMETRO
- PESO
- SIL
- SIL 2
- UL
BSP Connection
- G 1” B Male Flush/Male Flush Hygienic
- G 1/2” A Male DIN 3852-E / B Male / B Male Flush / B Male EN 837
- G 1/4” A Male DIN 3852-E / B Male EN 837 / B Male JIS B7505-76
- G 1/4” Female
- G 3/8” B Male EN 837
- 1/4” BSPT Male ISO 7
- 3/8” BSPT Male ISO 7
Electrical Connectors
- Angular Connector DIN EN 175301-803-A PG 9 / DIN 175301-803 A 1/2” NPT
- Bayonet Connector MIL-DTL-26482 (4-Pin / 6-Pin)
- Cable Outlet
- Circular Connector M12 x 1 (4-Pin) / M16 x 0.75 (5-Pin)
- Field Case
Materials of Construction
- Bayonet Connector: Al Cadmium-Plated
- Cable Outlet, Field Case: Nickel-Plated Brass
- Case, Cable Outlet, Circular/Bayonet Connector: Stainless Steel
- Circular Connector: Zn Nickel-Plated
Metric Connection
- M16 x 1.5 Female with Sealing Cone
- M20 x 1.5 Female with Sealing Cone
- M20 x 1.5 Male DIN 16288
NPT Connection
- 1/2” NPT Male ANSI/ASME B1.20.1
- 1/4” NPT Male ANSI/ASME B1.20.1
Overpressure & Static Pressure Limits
- Absolute Pressure (Overpressure Limit) - psi: 59 to 1,200 (kPa: 140 to 8,280, bar: 1.4 to 82.8)
- Gauge Pressure (Overpressure Limit) - psi: 20 to 21,700 (kPa: 140 to 700,000, bar: 1.4 to 7,000)
Power Supply
- With Field Case: 11-30 Vdc
- Without Field Case: 10-30 Vdc
Pressure Range
- bar: 0 to 6,000
- kPa: 0 to 600.000
- psi: 0 to 87,000
Repeatability
- Non-Repeatability ≤ ± 0.1 % of Span
Response Time
- ≤ 10 milliseconds (For Medium Temperatures Below -30° C)
- ≤ 2 milliseconds
Seat / Seal Material
- Copper
- EPDM
- FKM
- FPM
- NBR
- Stainless Steel
Shock
- Field Case with Optional Medium Temperature Range: 50 G
- Measuring Ranges > 1,000 bar, Optional Medium Temperature Ranges & Cable Outlet IP67 with Protection Cap: 100 G
- With Field Case: 600 G
- Without Field Case: 1,000 G
Span & Zero Adjustments
- Zero Point/Span: ± 5 % (Adjustment is Made Using Potentiometers Inside the Instrument)
Storage Temperature
- -20° to 80° C (-4° to 176° F)
Temperature Range
- -40° to 200° C (-40° to 392° F)
UNF/UNC Connection
- 7/16”-20 UNF Male BOSS SAE J514 E
- 9/16”-18 UNF Female F250-C
- 9/16”-18 UNF Male BOSS SAE J514 E
Vibration
- Field Case with Optional Medium Temperature Range: 2 G
- Measuring Ranges > 1,000 bar & Optional Medium Temperature Ranges: 5 G
- With Field Case & Able Outlet IP67 with Protection Cap: 10 G
- Without Field Case: 20 G