Xpert Specs at a Glance
Max. immersion length on request:
up to 15.000,00 mm (590'')
Response time:
depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
Max. process pressure (static):
at 20 °C: 240 bar (3481 psi)
Operating temperature range:
Type K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200...600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F)
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200...600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F)
Accuracy:
class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
Field of application
The iTHERM TMS11 MultiSens Linear Multipoint thermometer for oil & gas and chemical applications can be customized for various scenarios in compliance with the highest safety standards. It increases process safety by monitoring the temperature on a high number of measuring points along a line using only a single process connection. Easy process integration reduces installation time and thus maximizes plant availability.
Oil & Gas industry
Heavy chemical processes
Petrochemical industry
Features
- Features a primary thermowell for superior mechanical strength and an easy replacement of individual inserts, which are available either with TC or RTD technology
- Easy integration with inserts according to standards as per IEC 60584, ASTM E230 and IEC 60751
- Electrical and Pressure Directive compliance for an easy and fast process integration
- High degree of customization thanks to a modular product design for maximum flexibility, easy installation and maintenance
- Compliance to various protection classes for use in hazardous areas
- Possibility to replace individual inserts, even during operation
- Continuous thermowell integrity monitoring thanks to a pressure port for maximum process safety
Specifications
Brand
Industry
- Chemical
- Power & Energy
- Oil & Gas
- Other industries
Product Family
- iTHERM MultiSens
Thermometer
Characteristic / Application
- metric style
- imperial style
- easy-to-use
- suitable for hazardous areas
- process connection: flanged
- light chemical processes
- linear sensor distribution
- modular design
- replaceable sensors during operation
Thermowell / protection tube
- with one primary thermowell (for replaceable sensors and increased mechanical protection)
Insert / probe
- mineral insulated (MI) sensors in a primary thermowell
Outer diameter protection tube / Insert
- 48,3mm (1 1/2")
- 60,3mm (2")
- 76,1mm (2 1/2")
- 88,9mm (3")
Max. immersion length on request
- up to 15.000,00 mm (590'')
Material protection tube/ thermowell
- 1.4401 (316)
- 1.4435 (316L)
- 1.4541 (321)
- 1.4845 (310L)
- 1.4301 (304)
- 1.4307 (304L)
Process connection
- flange:
- 1 1/2 " ASME/ANSI B16.5 150
- ...900
- 2" ASME/ANSI B16.5 150
- 3" ASME/ANSI B16.5 150
- ..900
- DN40 EN/DIN 1092.1 PN10
- ...PN150
- DN50 EN/DIN 1092.1 PN10
- DN80 EN/DIN 1092.1 PN10
Tip shape
- straight
Operating temperature range
- Type K:
- max. 1.070 °C
- (max. 1.958 °F)
- Type J:
- max. 520 °C
- (max. 968 °F)
- Type N:
- max. 1.100 °C
- (max. 2.012 °F)
- Pt100 WW:
- -200...600 °C
- (-328…1.112 °F)
- Pt100 TF:
- -50…400 °C
- (-58…752 °F)
Max. process pressure (static)
- at 20 °C: 240 bar (3481 psi)
Accuracy
- class 1 acc. to IEC 60584
- class Special ASTM E230 and ANSI MC 96.1
- IEC60751 Class A
- IEC60751 Class AA
Response time
- depending on configuration:
- TC:
- t50 = 21 s
- t90 = 52 s
- RTD:
- t50 = 42 s
- t90 = 108 s
Integration head transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
- ATEX
- IECEx
- UL
- FM
- CSA
- NEPSI
Certification
- SIL (transmitter only)