IFOV with Standard Lens
- RSE300: 1.85 mRad
- RSE600: 0.93 mRad
Detector Resolution
- RES300: 320 x 240 - 76,800 pixels
- RSE600: 640 x 480 - 307,200 pixels
Thermal Sensitivity
- RSE300: 30 mK
- RSE600: 40 mK
Temperature Measurement Range
- -10° C to +1200° C
- 14° F to +2192° F
Accuracy
- ± 2° C or ± 2 %, whichever is greater
Operating Temperature
- -10° C to +50° C
- 14° F to 122° F
Electromagnetic Compatibility
- EN 61326-1: 2013 IEC 61326-1: 2013, (Industrial)
Vibration
- IEC 60068-2-26 (sinusoidal vibration): 3G, 11-200 Hz, 3 axis