AC Current: Jaw
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2 % ± 5-digits
AC Current: Flexible Current Probe
- Range: 2500 A
- Resolution: 1 A (≤ 2500 A), 0.1 A (≤ 999.9 A)
- Accuracy: 3 % ± 5-digits
DC Current
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2 % ± 5-digits
AC Voltage: Field Sense
- Range: 1000 V
- Resolution: 1 V (≤ 1000 V)
- Accuracy: ≤ 4/0 AWG 3 % ± 5-digits (45 Hz to 66 Hz)
AC Voltage: Test Leads
- Range: 600.0 V to 1000 V
- Resolution: 0.1 V (≤ 600.0 V), 1 V (≤ 1000 V)
- Accuracy: 1 % ± 5-digits
DC Voltage
- Range: 600.0 V to 1000 V
- Resolution: 0.1 V (≤ 600.0 V), 1 V (≤ 1000 V)
- Accuracy: 1 % ± 5-digits
mV dc
- Range: 500.0 mV
- Resolution: 0.1 mV
- Accuracy: 1 % ± 5-digits
Amps Frequency: Jaw
- Range: 45 Hz to 66 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5 % ± 5-digits
Amps Frequency: Flexible Current Probe
- Range 5.0 Hz to 500.0 Hz:
- Resolution: 0.1 Hz
- Accuracy: 0.5 % ± 5-digits
Capacitance
- Range: 1000 μF
- Resolution: 0.1 μF (≤ 100.0 μF), 1 μF (≤ 1000 μF)
- Accuracy: 1 % ± 4-digits
Operating Humidity
- ≤ 90 % RH (10° C to 30° C)
- ≤ 75 % RH (30° C to 40° C)
- ≤ 45 % RH (40° C to 50° C)
Safety
- IEC 61010-1: Pollution Degree 2
- IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
- IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
- IEC 61557-13: Class 2, ≤ 30 A/m