Condumax CLS15
Brand: Endress+HauserCondumax CLS15
Brand: Endress+HauserSpecs at a Glance
Process pressure:
max. 12 bar at 20°C
(174 psi at 68°F)
(174 psi at 68°F)
Process temperature:
max. 130°C (150°C / 30 min.)
(max. 266°F (302°F/30 min.)
(max. 266°F (302°F/30 min.)
Measuring range:
k=0,01: 0-20 µS/cm
k=0,1: 0-200 µS/cm
k=0,1: 0-200 µS/cm
Field of application
Condumax CLS15 is the ideal choice for conductivity measurement in low measuring ranges. It performs reliably and accurately in a wide range of applications - even in hazardous areas. Designed for low maintenance and a long operating life, the sensor offers real value for money.
Condumax CLS15 measures conductivity in pure and ultrapure water applications for the monitoring and control of:
- Ion exchangers
- Reverse osmosis
- Cooling water
- Distillation
- Chip cleaning
- The sensor can be used in power plants for:
- Degassed conductivity
- pH measurement with differential conductivity
- With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.
Features
- Reliable and accurate measuring values at low conductivities
- Easy to clean thanks to polished measuring surfaces
- Sterilizable
- Robust design for high durability
- Different cell constants provide a wide measuring range
- Quality certificate stating the individual cell constant
Specifications
Brand
Industry
- Chemical
- Water, Wastewater & Waste
- Food & Beverage
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Pulp & Paper (incl. Printing)
- Other industries
- Life Science
Product Family
- Condumax
Conductivity
Application
- Water, power plant, process
Characteristic
- 2-electrode conductivity cell for pure and ultrapure water
Measuring range
- k=0,01: 0-20 µS/cm
- k=0,1: 0-200 µS/cm
Measuring principle
- Conductive conductivity cell with polished stainless steel electrodes
Design
- 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished
Material
- Electrode: 1.4435
- Electrode shaft: PES
Dimension
- Electrode diameter: 16 mm
- (0.62 inch)
- Electrode length: appr. 55 mm
- (2.14 inch)
Process temperature
- max. 130°C (150°C / 30 min.)
- (max. 266°F (302°F/30 min.)
Process pressure
- max. 12 bar at 20°C
- (174 psi at 68°F)
Temperature sensor
- Pt100
Ex certification
- ATEX
Connection
- Process connection: 1/2" NPT, 3/4" NPT, 1 1/2" Clamp
- cable : 4-pole SXP connector or fixed cable
Ingress protection
- IP67
Additional certifications
- Calibration certification of the cell constante.