Field Transmitter iTEMP TMT142B

Brand: Endress+Hauser

Field Transmitter iTEMP TMT142B

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Lean Lean

Specs at a Glance

Accuracy:
(Pt100, -50...200 °C) <=0,1 K
(Pt100, -58...392 °F) <=0,18 °F

Field of application

The iTEMP TMT142B comes in a robust, compact single-chamber field housing. Highest performance in critical control applications and harsh environments such as hazardous areas characterize this single-channel temperature transmitter. Its backlit display offers clear process and diagnostic information in the field. The integrated Bluetooth® interface facilitates remote device configuration and maintenance routine, regardless of the mounted position. Inputs for resistance sensors (RTD), thermocouple (TC), resistances (Ω) and voltage transmitters (mV) are converted to a 4 to 20 mA signal and HART ® 7 communication.

Features

  • Reliable, long-term stable and accurate temperature measurement even under harsh environmental conditions thanks to a pressure-encapsulated single-chamber housing and integrated overvoltage protection.

Specifications

Product Family

  • iTEMP

Temperature transmitters

Input

  • 1 x RTD, TC, Ohm, mV

Output

  • 1 x analog 4...20 mA / HART

Auxiliary power supply

  • 11…36 V DC (standard-version)
  • 11...30 V DC (Ex ia)

Communication

  • HART-protocol
  • Bluetooth® wireless technology

Installation

  • in field

Accuracy

  • (Pt100, -50...200 °C) <=0,1 K
  • (Pt100, -58...392 °F) <=0,18 °F

Galvanic isolation

  • yes

Certification

  • ATEX II1G Ex ia IIC T6
  • ATEX II3G Ex ic IIC T6 Gc
  • ATEX II3D Ex tc IIIC Dc
  • ATEX II3G Ex nA IIC T6 Gc
  • ATEX IECEx II1G Ex ia IIC T6, II2D Ex ia IIIC
  • ATEX II3G Ex nA IIC Gc, II3D
  • ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
  • CSA C/US General Purpose
  • CSA C/US IS, NI I/1+2/A-D
  • CSA C/US XP, NI, DIP I, II, III/1+2/A-G
  • EAC Ex ia IIC T6 Ga
  • EAC Ex d IIC T6 Gb
  • IECEx Ex d T6 Gb, Ex tb IIIC Db
  • INMETRO Ex ia IIC T6 Ga
  • INMETRO Ex d T6 Gb, Ex tb IIIC Db
  • INMETRO Ex nA IIC T6 Gc
  • NEPSI Ex ia IIC T6 Ga
  • NEPSI Ex d IIC T6 Gb
  • NEPSI Ex nA II T6 Gc
  • UK II1G Ex ia IIC T6 Ga
  • UK II3G Ex ic IIC T6 Gc
  • UK II2D Ex tb IIIC Db
  • UK II3D Ex tc IIIC Dc
  • UK II1G Ex ia IIC T6 Ga, II2D Ex ia IIIC Db
  • UK II3G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
  • UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
  • ATEX IECEx II1G Ex ia IIC T6 Ga
  • ATEX IECEx II2D Ex tb IIIC Db
  • ATEX IECEx II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
show more