ATE-2 Handheld Calibrator

Brand: Ashcroft Inc
Does not ship to OH, United States

The Ashcroft® ATE-2 handheld digital calibrator is a portable, multifunction instrument performing precision measurement of pressure, temperature, current or voltage.

The base unit includes application-specific firmware for the convenient calibration and setting of measurement and control devices, as well as logging of associated data.

In addition, the ATE-2 has the ability to interface with a computer, data acquisition system or terminal emulator via the standard USB interface. 

An ideal instrument when precision calibration and traceability are required.

Features
  • Interchangeable pressure modules with ranges from 0.25 in. H2O up to 10,000 psi
  • Large LCD display (1.5" x 2.5")
  • FM, CSA and ATEX Intrinsically safe versions for Hazardous Locations (Options)
  • Dual sensor module bay for interchangeable modules
  • Data logging capability up to 16,000 records
  • USB communications port SD memory card slot
  • SD memory card slot
  • Standard firmware features – min./max., tare, programmable damping, percent function, and switch test Built in Power supply to power device under test

Specifications

Pressure Range

  • 0.25 in. H2O up to 10,000 psi

Accuracy

  • Low Pressure Module: ±0.1%, ±0.06, ±0.7% of span
  • Medium / High Pressure Module: ±0.025%, ±0.05%, ±0.1% of span

LCD Display

  • 2.5" (W) x 1.5" (H) displays 3 simultaneous measurements, back light, flip screen capability

Electrical Connection

  • 4 mm Banana Jacks

Loop Power Supply

  • 24 Vdc, 35 mA maximum (non I.S. only)

Operating Temperature

  • -20° to 49° C (-4° to 120° F)

Storage Temperature

  • -20° to 70° C (-4° to 158° F)

Update Rate

  • 100 ms – 1 module installed
  • 200 ms – 2 modules installed
  • 300 ms – 2 modules installed and external input

Resolution

  • ± 0.001 % of Span, 99,999 Count

Electrical Measurement

  • 0-20 mA or 0-30 Vdc

Temperature Effect

  • ± 0.001 % of Span/°F over Compensated Range from Reference Temperature of 70° F (± 3° F)
  • AM2-1 Low, Medium / High Pressure Module: ± 0.004 % of Span/°F over Compensated Range from Reference Temperature Range of 70° F (± 3°)

Power Requirement

  • (4) AA Batteries or via USB power supply or USB universal AC adapter 100-240 Vac, 50/60 Hz included

Battery Life

  • Up to 40 hours battery with 2 modules installed

Approvals & Certifications

  • ATEX Ex
  • CE/UKCA
  • FM
  • UL
  • FCC
  • CSA

Enclosure Rating

  • IP65/NEMA 4X

  • Gas Pipeline / Transmission
  • Refineries
  • Chemical & Petrochemical Plants
  • Power Generation
  • Industrial Market:
    • Test & Measurement
    • Calibration Laboratories
  • Medical and Life Sciences:
    • Pharmaceutical & Biotech
    • Hospitals & Medical Research
show more