Type 77 T77 Vacuum Regulator
Brand: Marsh Bellofram Group of CompaniesBellofram’s Type 77 Vacuum Regulator incorporates a fixed negative 15 psig bias spring to maintain vacuum outputs up to 29" Hg. An adjustable opposing range spring increases controlled pressure outputs up to 150 psig.
Output pressure droop under varying downstream flow conditions is minimized by use of an aspirator tube which adjusts the air supply valve opening in accordance with flow velocity.
A balanced supply valve, utilizing a reinforced rolling diaphragm, keeps regulator output virtually immune to changes in supply pressure.
Stack-up construction makes the Type 77 easily serviceable, without removing it from the air line.
Features
- Single-unit control of pressures from 29″ Hg vacuum to 150 psi
- Flow capacity up to 40 SCFM
- Dampening action of aspirator tube maintains stable output pressure
- Output virtually unaffected by changes in supply pressure
- Can be disassembled and serviced without removing from line
Specifications
Sensitivity
- 1/2" (1.3 cm) Water Column
Flow Capacity
- 2.5 scfm (71 L/M) @ 29 inHg (740 mmHg) Vacuum
- 40 scfm (1,130 L/M) @ 100 psig (6.9 bar) Supply, 20 psig (1.4 bar) Output
Effect of Supply Pressure Variation (25 psig / 1.7 bar) on Outlet Pressure
- Less than 0.1 psig (0.01 bar)
Exhaust Capacity at 5 psig (0.34 bar) Above Set Point
- 4 scfm (1,13 LPM)
Maximum Supply Pressure
- 250 psig (17.2 bar)
Ambient Temperature Limits
- -40° to 200° F (-40° to 93° C)
Output Pressure Ranges
- Vacuum to 150 psig (10.3 bar)
- Vacuum to 100 psig (6.9 bar)
- Vacuum to 30 psig (2.1 bar)
- Vacuum to 10 psig (0.7 bar)
- Vacuum to 2 psig (0.1 bar)
Total Air Consumption at Maximum Output
- 6 SCFH (2.8 LPM)
Port Size
- 1/4" BSPT, 3/8" BSPT
- 1/4" NPT, 3/8" NPT
Materials of Construction
- Body: Die Cast Aluminum with Vinyl Paint
- Diaphragm: Buna-N with Polyester Fabric
- Trim: Stainless Steel, Brass, Plated Steel, Acetal and Buna-N
- Knob: Phenolic Plastic
- Spring: Music wire
Mounting Options
- Pipe
- Panel
- Bracket
- Sample Collecting Systems
- Air Quality Monitoring
- Parts Coating Operations
- May Be Installed Upstream or Downstream From the Vacuum Pump