Deltabar Evo 2 PMD75B/78B PMD78B
Brand: Endress+HauserDeltabar Evo 2 PMD75B/78B PMD78B
Brand: Endress+Hauser
Heartbeat Technology Specs at a Glance
Main wetted parts:
316L, AlloyC,
Tantal, Monel
PTFE, Gold
Tantal, Monel
PTFE, Gold
Accuracy:
Standard:
up to 0.1 %
up to 0.1 %
Process temperature:
-40°C...+400°C
(-40°F...+752°F)
(-40°F...+752°F)
Material process membrane:
316L, AlloyC,
Tantal,
Monel
PTFE
Gold
Tantal,
Monel
PTFE
Gold
Pressure measuring range:
100 mbar...40 bar
(1.5psi...600 psi)
(1.5psi...600 psi)
Measuring cell:
100 mbar...40 bar
(1.5 psi...600 psi)
(1.5 psi...600 psi)
Field of application
Differential pressure, piezoresistive.
Differential pressure transmitter.
Diaphragm seal.
Application: level.
Metal membrane: welded,
high process temperatures.
Specifications
Brand
Product Family
- Deltabar
Continuous / Liquids
Characteristic / Application
- Smart differential pressure transmitter with one or two capillaries, full range of certifications and Heartbeat Technology.
- Intuitive and clear wizards for commissioning, proof tests and verification.
Specialities
- Heartbeat Technology,
- Bluetooth® Operation and maintenance SmartBlue App,
- LED Module,
- RFID TAG for easy identification,
- Plug and play functionalities
- HistoROM
Supply / Communication
- Ex d, Ex e, non-Ex::
- 10.5...35V DC
- Ex i: 10.5...30V DC
Accuracy
- Standard:
- up to 0.1 %
Long term stability
- 0.025 % of URL/ year
- 0.05 % of URL/ 5 years
- 0.10 % of URL/ 10 years
Ambient temperature
- -54°C...+85°C
- (-65°F...+185°F)
Process temperature
- -40°C...+400°C
- (-40°F...+752°F)
Process pressure / max. overpressure limit
- 160 bar (2.400 psi)
Pressure measuring range
- 100 mbar...40 bar
- (1.5psi...600 psi)
Main wetted parts
- 316L, AlloyC,
- Tantal, Monel
- PTFE, Gold
Process connection
- Thread:
- MNPT1/2, G1/2
- Flange:
- NPS 2"...4", DN50...100
Max. measurement distance
- 160 m (525 ft) H2O
Communication
- 4...20 mA HART
- PROFIBUS PA
- PROFINET with Ethernet-APL
- Bluetooth® wireless
- technology and app (optional)
Certificates / Approvals
- ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals
- SIL
Design approvals
- EN 10204-3.1,
- NACE MR0175,
- NACE MR0103
Options
- Touch control display
Application limits
- Keine
Pressure
Characteristic
- Specialist with one or two capillaries for accurate differential pressure measurement.
- Intuitive and clear wizards for commissioning, proof tests and verification.
Supply voltage
- Ex d, Ex e, non-Ex:
- 10.5...35V DC
- Ex i: 10.5...30V DC
Reference Accuracy
- Standard:
- up to 0.1 %
Long term stability
- 0.025 % of URL/ year
- 0.05 % of URL/ 5 years
- 0.10 % of URL/ 10 years
Process temperature
- -70°C...+400°C
- (-x°F...+752°F)
Ambient temperature
- -40°C...+85°C
- (-40°F...+185°F)
Measuring cell
- 100 mbar...40 bar
- (1.5 psi...600 psi)
Smallest calibratable span
- 5 mbar (0.075 psi)
Vacuum resistance
- 50 mbar (0.73 psi)
Max. Turn down
- 100:1
Max. overpressure limit
- 240 bar
- (3600 psi)
Process connection
- Thread: MNPT1/2, G1/2
- Flange: NPS 2"...4", DN50...100
Material process membrane
- 316L, AlloyC,
- Tantal,
- Monel
- PTFE
- Gold
Material gasket
- PTFE, FKM,
- EPDM, FFKM
Fill fluid
- Silicone oil,
- inert oil,
- vegetable oil,
- low- / high temperature oil
Material housing
- Aluminium, 316L
Communication
- 4...20 mA HART
- PROFIBUS PA
- PROFINET with Ethernet-APL
- Bluetooth® wireless
- technology and app (optional)
Certificates / Approvals
- ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals
- SIL
Design approvals
- EN10204-3.1,
- NACE MR0175,
- NACE MR0103
Specialities
- Heartbeat Technology,
- Bluetooth® Operation and maintenance SmartBlue App,
- LED Module,
- RFID TAG for easy identification,
- Plug and play functionalities,
- HistoROM